In vivo dosimetry in intraoperative electron radiotherapy: microMOSFETs, radiochromic films and a general-purpose linac.

Juan López-Tarjuelo, Ana Bouché-Babiloni, Virginia Morillo-Macías, Noelia de Marco-Blancas, Agustín Santos-Serra, Juan David Quirós-Higueras, Carlos Ferrer-Albiach

Abstract readClinical TrialComparative Study
PubMed Publisher
In one paragraph

Trial report in Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.8field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Present state and issues in IORT Physics.Radiation oncology (London, England) · 2017
    Review
  3. Article
  4. Article
  5. Practical issues regarding angular and energy response in in vivo intraoperative electron radiotherapy dosimetry.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Juan López-TarjueloServicio de Radiofísica y Protección Radiológica, Consorcio Hospitalario Provincial de Castellón, Avenida Dr. Clará, nº 19, 12002, Castellón de la Plana, Spain, lopez_juatar@gva.es.
Ana Bouché-Babiloni
Virginia Morillo-Macías
Noelia de Marco-Blancas
Agustín Santos-Serra
Juan David Quirós-Higueras
Carlos Ferrer-Albiach
Consorcio Hospitalario Provincial de Castellón · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIn vivo dosimetry is desirable for the verification, recording, and eventual correction of treatment in intraoperative electron radiotherapy (IOERT). Our aim is to share our experience of metal oxide semiconductor field-effect transistors (MOSFETs) and radiochromic films with patients undergoing IOERT using a general-purpose linac. MATERIALS AND

methodsWe used MOSFETs inserted into sterile bronchus catheters and radiochromic films that were cut, digitized, and sterilized by means of gas plasma. In all, 59 measurements were taken from 27 patients involving 15 primary tumors (seven breast and eight non-breast tumors) and 12 relapses. Data were subjected to an outliers' analysis and classified according to their compatibility with the relevant doses. Associations were sought regarding the type of detector, breast and non-breast irradiation, and the radiation oncologist's assessment of the difficulty of detector placement. At the same time, 19 measurements were carried out at the tumor bed with both detectors.

resultsMOSFET measurements ([Formula: see text]  = 93.5 %, sD  =  6.5 %) were not significantly shifted from film measurements ([Formula: see text]  =  96.0 %, sD  =  5.5 %; p  =  0.109), and no associations were found (p = 0.526, p = 0.295,  and p = 0.501, respectively). As regards measurements performed at the tumor bed with both detectors, MOSFET measurements ([Formula: see text]  =  95.0 %, sD  =  5.4 % were not significantly shifted from film measurements ([Formula: see text]  =  96.4 %, sD  =  5.0 %; p  =  0.363).

conclusionIn vivo dosimetry can produce satisfactory results at every studied location with a general-purpose linac. Detector choice should depend on user factors, not on the detector performance itself. Surgical team collaboration is crucial to success.

Indexed as

Transistors, ElectronicElectronsEquipment DesignEquipment Failure AnalysisFilm DosimetryHumansIntraoperative CareNeoplasmsParticle AcceleratorsRadiotherapy, AdjuvantReproducibility of ResultsSensitivity and Specificity

Identifiers

PMID24965479
OpenAlexW1229425810

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.