Evidence map›Paper›PMID 24957974›Full record

ArticleCritical care (London, England)2014

Automatic protective ventilation using the ARDSNet protocol with the additional monitoring of electrical impedance tomography.

Anake Pomprapa, David Schwaiberger, Philipp Pickerodt, Onno Tjarks, Burkhard Lachmann, Steffen Leonhardt

Open access · goldAbstract read
In one paragraph

Article in Critical care (London, England), 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 28 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Review
  9. Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Anake Pomprapa
David Schwaiberger
Philipp Pickerodt
Onno Tjarks
Burkhard Lachmann
Steffen Leonhardt
Charité - Universitätsmedizin Berlin · DERWTH Aachen University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAutomatic ventilation for patients with respiratory failure aims at reducing mortality and can minimize the workload of clinical staff, offer standardized continuous care, and ultimately save the overall cost of therapy. We therefore developed a prototype for closed-loop ventilation using acute respiratory distress syndrome network (ARDSNet) protocol, called autoARDSNet.

methodsA protocol-driven ventilation using goal-oriented structural programming was implemented and used for 4 hours in seven pigs with lavage-induced acute respiratory distress syndrome (ARDS). Oxygenation, plateau pressure and pH goals were controlled during the automatic ventilation therapy using autoARDSNet. Monitoring included standard respiratory, arterial blood gas analysis and electrical impedance tomography (EIT) images. After 2-hour automatic ventilation, a disconnection of the animal from the ventilator was carried out for 10 seconds, simulating a frequent clinical scenario for routine clinical care or intra-hospital transport.

resultsThis pilot study of seven pigs showed stable and robust response for oxygenation, plateau pressure and pH value using the automated system. A 10-second disconnection at the patient-ventilator interface caused impaired oxygenation and severe acidosis. However, the automated protocol-driven ventilation was able to solve these problems. Additionally, regional ventilation was monitored by EIT for the evaluation of ventilation in real-time at bedside with one prominent case of pneumothorax.

conclusionsWe implemented an automatic ventilation therapy using ARDSNet protocol with seven pigs. All positive outcomes were obtained by the closed-loop ventilation therapy, which can offer a continuous standard protocol-driven algorithm to ARDS subjects.

Indexed as

AnimalsCarbon DioxideElectric ImpedanceFemaleHydrogen-Ion ConcentrationMaleMonitoring, PhysiologicOxygenPilot ProjectsPositive-Pressure RespirationPulmonary VentilationRespiratory Distress SyndromeSwineTidal VolumeTomographyCarbon DioxideOxygen

Identifiers

PMID24957974
PMCPMC4230798
OpenAlexW2138926201

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390