Evidence map›Paper›PMID 24951811›Full record

ArticleJournal of clinical microbiology2014

Identification of microorganisms by FilmArray and matrix-assisted laser desorption ionization-time of flight mass spectrometry prior to positivity in the blood culture system.

Mohammed Almuhayawi, Osman Altun, Kristoffer Strålin, Volkan Ozenci

Abstract readComparative StudyEvaluation Study
In one paragraph

Article in Journal of clinical microbiology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Clinical Utility of the FilmArrayMicroorganisms · 2023
    Article
  2. Article
  3. Syndromic Panel-Based Testing in Clinical Microbiology.Clinical microbiology reviews · 2018
    Review
  4. Article
  5. Article
  6. Individualized Approaches Are Needed for Optimized Blood Cultures.Clinical infectious diseases : an official publication of the Infectious Diseases Society of America · 2016
    Article
  7. Article
  8. Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mohammed AlmuhayawiDivision of Clinical Microbiology, Karolinska Institutet, Karolinska University Hospital, Huddinge, Stockholm, Sweden King Abdul-Aziz University, Faculty of Medicine, Department of Microbiology, Jeddah, Saudi Arabia.
Osman AltunDivision of Clinical Microbiology, Karolinska Institutet, Karolinska University Hospital, Huddinge, Stockholm, Sweden.
Kristoffer StrålinDepartment of Medicine, Division of Infectious Diseases, Karolinska Institutet, Karolinska University Hospital, Huddinge, Stockholm, Sweden.
Volkan OzenciDivision of Clinical Microbiology, Karolinska Institutet, Karolinska University Hospital, Huddinge, Stockholm, Sweden volkan.ozenci@karolinska.se.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this study, we investigated the performance of the FilmArray and matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) in identifying microorganisms from blood culture (BC) bottles prior to positivity. First, we used simulated BacT/Alert FA Plus BC bottles with five each for Escherichia coli and Staphylococcus aureus isolates. The FilmArray identified all 10 isolates before BC positivity with 9/10 at 5 h and 1 at 7.5 h after incubation in the BC system. MALDI-TOF MS failed to identify the isolates prior to positivity. When the bottles were incubated for 2.5 h at room temperature (RT) before we put them into the BC system, the FilmArray identified 6/10 at 2.5 h and the remaining 4 at 5 h. Finally, we tested simulated BC bottles after incubation at RT. Interestingly, 9/10 isolates were identified with the FilmArray after 8 h of incubation at RT. Second, we studied clinical BC bottles in quadruplicate. When three-fourths of the parallel bottles signaled positive, the FilmArray was run on the fourth nonsignaled bottle and was found to be positive in 14/15 such cases. Third, we analyzed the performance of the FilmArray in the identification of microorganisms from clinical BC bottles before incubation in the system. Two milliliters of broth from 400 BC bottles was collected after arrival at the laboratory and stored at -70°C. Sixteen bottles later signaled positive in the system. When the frozen broth from these bottles was analyzed, the FilmArray identified all the microorganisms in 8/16 bottles prior to incubation in the BC system. This study shows that the FilmArray can identify microorganisms from BC bottles prior to positivity and in some cases even prior to incubation in the BC system.

Indexed as

BacteriaBloodCandidaHumansMicrobiological TechniquesMolecular Diagnostic TechniquesMultiplex Polymerase Chain ReactionSepsisSpectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationTemperatureTime Factors

Identifiers

PMID24951811
PMCPMC4313143

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.