ArticleBiomedical optics express2014
Microscope-integrated intraoperative OCT with electrically tunable focus and heads-up display for imaging of ophthalmic surgical maneuvers.
Article in Biomedical optics express, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 45 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
45 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Clinical applications for intraoperative optical coherence tomography: a systematic review.Eye (London, England) · 2022Pooled it
- Depth-of-focus enhancement in optical coherence tomography via a cascaded image registration and fusion network for multi-focus imaging.Journal of biomedical optics · 2026Article
- Magnification-Invariant Retinal Distance Estimation for Vitreoretinal Surgery Using a Laser Aiming Beam.The international journal of medical robotics + computer assisted surgery : MRCAS · 2025Article
- Intraoperative Spectrally Encoded Coherence Tomography and Reflectometry (iSECTR) for Ophthalmic Surgical Guidance.Translational vision science & technology · 2025Article
- Adaptive contour-tracking to aid wide-field swept-source optical coherence tomography imaging of large objects with uneven surface topology.Biomedical optics express · 2024Article
- Visualization of surgical maneuvers using intraoperative real-time volumetric optical coherence tomography.Biomedical optics express · 2023Article
- Quantitative measurements of intraocular structures and microinjection bleb volumes using intraoperative optical coherence tomography.Biomedical optics express · 2023Article
- Automated instrument-tracking for 4D video-rate imaging of ophthalmic surgical maneuvers.Biomedical optics express · 2022Article
- Combined anterior segment OCT and wavefront-based autorefractor using a shared beam.Biomedical optics express · 2021Article
- Microscope-Integrated OCT-Guided Volumetric Measurements of Subretinal Blebs Created by a Suprachoroidal Approach.Translational vision science & technology · 2021Article
- A Review of Robotic and OCT-Aided Systems for Vitreoretinal Surgery.Advances in therapy · 2021Review
- Comprehensive review of surgical microscopes: technology development and medical applications.Journal of biomedical optics · 2021Review
- Optical Coherence Tomography-Guided Robotic Ophthalmic Microsurgery via Reinforcement Learning from Demonstration.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2020Article
- Extratympanic Observation of Middle and Inner Ear Structures in Rodents Using Optical Coherence Tomography.Clinical and experimental otorhinolaryngology · 2020Article
- Intraoperative Optical Coherence Tomography Imaging in Corneal Surgery: A Literature Review and Proposal of Novel Applications.Journal of ophthalmology · 2020Article
- Speeded-Up Focus Control of Electrically Tunable Lens by Sparse Optimization.Scientific reports · 2019Article
- Depth-Based, Motion-Stabilized Colorization of Microscope-Integrated Optical Coherence Tomography Volumes for Microscope-Independent Microsurgery.Translational vision science & technology · 2018Article
- THE INTEGRATIVE SURGICAL THEATER: Combining Intraoperative Optical Coherence Tomography and 3D Digital Visualization for Vitreoretinal Surgery in the DISCOVER Study.Retina (Philadelphia, Pa.) · 2018Article
- Real-time visualization and interaction with static and live optical coherence tomography volumes in immersive virtual reality.Biomedical optics express · 2018Article
- Real-time corneal segmentation and 3D needle tracking in intrasurgical OCT.Biomedical optics express · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
We present novel optical and mechanical designs for a microscope-integrated intraoperative optical coherence tomography (iOCT) system with enhanced function and ergonomics for visualization of ophthalmic surgical maneuvers. Integration of an electrically tunable lens allows rapid focal plane adjustment and iOCT imaging of both anterior and posterior segment tissue microstructures while maintaining parfocality with the ophthalmic surgical microscope. We demonstrate novel visualization of instrument positions relative to tissue layers of interest as colormap overlays onto en face OCT data, which may provide integrative display of volumetric information during surgical maneuvers. Finally, we implement a heads-up display system to provide real-time feedback as proof-of-principle for iOCT-guided ophthalmic surgery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.