ArticleJournal of neurogastroenterology and motility2014
Impedance Analysis Using High-resolution Impedance Manometry Facilitates Assessment of Pharyngeal Residue in Patients With Oropharyngeal Dysphagia.
Article in Journal of neurogastroenterology and motility, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it, 13 citations in OpenAlex.
- A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2019Pooled it
- Adequate Number of Swallows for Pharyngeal Pressure Measurement of a Subject using High-resolution Manometry.International archives of otorhinolaryngology · 2021Article
- Perceived Professional and Institutional Factors Influencing Clinical Adoption of Pharyngeal High-Resolution Manometry.American journal of speech-language pathology · 2020Article
- Safety of flexible endoscopic evaluation of swallowing examination in gastroenterological practice.The Turkish journal of gastroenterology : the official journal of Turkish Society of Gastroenterology · 2019Article
- Distal contractile to impedance integral ratio assist the diagnosis of pediatric ineffective esophageal motility disorder.Pediatric research · 2018Article
- Dysphagia Practice in 2035: Beyond Fluorography, Thickener, and Electrical Stimulation.Seminars in speech and language · 2016Article
- Application and Interpretation of High-resolution Manometry for Pharyngeal Dysphagia.Journal of neurogastroenterology and motility · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
BACKGROUND/
aimsImpedance analysis using high-resolution impedance manometry (HRIM) enables the recognition of pharyngeal residue in patients with oropharyngeal dysphagia. The aims of this study were to evaluate appropriate criteria for impedance analysis in a large patient cohort, as well as the diagnostic accuracy and agreement of analysis performed by HRIM trainees.
methodsWe reviewed 33 controls (13 males; median age, 61.2 years) and 104 oropharyngeal dysphagia patients (61 males; median age, 70.4 years) who underwent a flexible endoscopic evaluation of swallowing study (FEES) and HRIM. Two experts compared the pharyngeal residue on FEES and impedance color pattern at 1,000, 1,500 and 2,000 Ω of the impedance bar. Three trainees were given a 60 minutes tutorial to determine the diagnostic accuracy and agreement of this analysis.
resultsThe diagnostic sensitivity of experts for predicting liquid residue was 73.1% for 1,000 Ω, 96.2% for 1,500 Ω and 100% for 2,000 Ω. Significantly higher sensitivity was observed at 1,500 Ω compared to 1,000 Ω (P < 0.001). The diagnostic specificity of experts for liquid residue was 98.3% for 1,000 Ω, 96.6% for 1,500 Ω and 83.1% for 2,000 Ω. There was a higher specificity at 1,500 Ω compared to 2,000 Ω (P = 0.008). The κ value among the 3 trainees was 0.89 and the diagnostic accuracy of the trainees for liquid residue was comparable to that of the experts.
conclusionsThe impedance analysis at 1,500 Ω provides more accurate information for the detection of liquid residue, irrespective of the level of expertise.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials