Evidence map›Paper›PMID 24922593›Full record

ArticleAnalytical chemistry2014

Application of screening experimental designs to assess chromatographic isotope effect upon isotope-coded derivatization for quantitative liquid chromatography-mass spectrometry.

Szabolcs Szarka, Katalin Prokai-Tatrai, Laszlo Prokai

Abstract read
In one paragraph

Article in Analytical chemistry, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.5field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 36 citations in OpenAlex.

  1. Article
  2. Article
  3. Chemical Isotope Labeling LC-MS for Metabolomics.Advances in experimental medicine and biology · 2021
    Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. A High Resolution/Accurate Mass (HRAM) Data-Dependent MSJournal of the American Society for Mass Spectrometry · 2017
    Article
  10. Article
  11. Ion Mobility Separation of Peptide Isotopomers.Journal of the American Society for Mass Spectrometry · 2016
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Szabolcs SzarkaDepartment of Pharmacology and Neuroscience, and ‡Department of Pharmaceutical Sciences, UNT System College of Pharmacy, University of North Texas Health Science Center , 3500 Camp Bowie Boulevard, Fort Worth, Texas 76107-2699, United States.
Katalin Prokai-Tatrai
Laszlo Prokai
University of North Texas · USUniversity of North Texas Health Science Center · US

Funding

Survey of Age-Associated Carbonylation of Brain ProteinsR01AG025384 · NIA · UNIVERSITY OF NORTH TEXAS HLTH SCI CTR · PI PROKAI, LASZLO · 2004 to 2008
$1.4M
NIA NIH HHS AG025384NIA NIH HHS R01 AG025384
6 · The paper itself

Abstract

Isotope effect may cause partial chromatographic separation of labeled (heavy) and unlabeled (light) isotopologue pairs. Together with a simultaneous matrix effect, this could lead to unacceptable accuracy in quantitative liquid chromatography-mass spectrometry assays, especially when electrospray ionization is used. Four biologically relevant reactive aldehydes (acrolein, malondialdehyde, 4-hydroxy-2-nonenal, and 4-oxo-2-nonenal) were derivatized with light or heavy (d3-, (13)C6-, (15)N2-, or (15)N4-labeled) 2,4-dinitrophenylhydrazine and used as model compounds to evaluate chromatographic isotope effects. For comprehensive assessment of retention time differences between light/heavy pairs under various gradient reversed-phase liquid chromatography conditions, major chromatographic parameters (stationary phase, mobile phase pH, temperature, organic solvent, and gradient slope) and different isotope labelings were addressed by multiple-factor screening using experimental designs that included both asymmetrical (Addelman) and Plackett-Burman schemes followed by statistical evaluations. Results confirmed that the most effective approach to avoid chromatographic isotope effect is the use of (15)N or (13)C labeling instead of deuterium labeling, while chromatographic parameters had no general influence. Comparison of the alternate isotope-coded derivatization assay (AIDA) using deuterium versus (15)N labeling gave unacceptable differences (>15%) upon quantifying some of the model aldehydes from biological matrixes. On the basis of our results, we recommend the modification of the AIDA protocol by replacing d3-2,4-dinitrophenylhydrazine with (15)N- or (13)C-labeled derivatizing reagent to avoid possible unfavorable consequences of chromatographic isotope effects.

Indexed as

AcroleinAldehydesAnimalsCarbon IsotopesChromatography, LiquidDeuteriumFemaleIsotope LabelingMalondialdehydeMice, Inbred StrainsNitrogen IsotopesSpectrometry, Mass, Electrospray IonizationTandem Mass SpectrometryTemperature4-hydroxy-2-nonenal4-oxo-2-nonenalAcroleinAldehydesCarbon IsotopesDeuteriumMalondialdehydeNitrogen Isotopes

Identifiers

PMID24922593
PMCPMC4215859
OpenAlexW2321028225

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.