ArticleClinical neuroradiology2015
The Value of syngo DynaPBV Neuro During Neuro-Interventional Hypotensive Balloon Occlusion Test.
Article in Clinical neuroradiology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 11 citations in OpenAlex.
- Evaluation of Cerebral Hyperperfusion After Carotid Artery Stenting Using C‑Arm CT Measurements of Cerebral Blood Volume.Clinical neuroradiology · 2018Trial
- Vascular interventional strategies for recurrent nasopharyngeal carcinoma: diagnostic and therapeutic perspectives.Frontiers in oncology · 2025Article
- Pooled blood volume measured by final flat-panel detector computed tomography predicts outcome after endovascular thrombectomy for acute ischemic stroke.World neurosurgery: X · 2023Article
- Flat Detector CT with Cerebral Pooled Blood Volume Perfusion in the Angiography Suite: From Diagnostics to Treatment Monitoring.Diagnostics (Basel, Switzerland) · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 5 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimThis study explored the value of flat detector computed tomography based brain perfusion imaging in assessing patient's tolerance prior to the permanent internal carotid artery occlusion. MATERIALS AND
methodsTen patients diagnosed with neurovascular diseases through digital subtracted angiography (DSA) were enrolled into this study. Temporary balloon occlusion test (BOT) was performed for each patient with hypotensive challenge. During the test, parametric color-coded quantitative DSA (CCQ-DSA) was generated to evaluate the venous filling symmetry on both hemispheres. In addition, cerebral blood volume (CBV) maps were acquired before and during the test. Regions of interests were defined to quantitatively extract CBV value from affected and unaffected hemispheres and calculate relative CBV (rCBV), indicating perfusion symmetry.
resultsAll the patients showed good perfusion symmetry before the test with rCBV close to 1.00. During the test, good perfusion symmetry was detected in 7 patients with averaged rCBV 1.03 ± 0.06. Only short venous delay and no ischemic complications were recognized. One patient had neither neurologic deficits nor long venous delay detected, however, showed hyper-perfusion in specific regions in the CBV maps. Two patients failed to pass the test, which showed significantly low CBV value from the affected hemisphere with maximum rCBV reduction close to 45%.
conclusionCBV map had in general good consistency with clinical manifestations as well as venous filling in the BOT. Besides, it may provide further evidence of hemodynamic variations and delayed ischemic complications, and thus, had a potential to reduce risks and increase treatment safety.