ArticleFrontiers in neuroinformatics2014
Accumulated source imaging of brain activity with both low and high-frequency neuromagnetic signals.
Article in Frontiers in neuroinformatics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT00600717 (Localizing Functional Brain Cortices and Epileptogenic Zones With High Frequency Brain Signals), which is not on this map. Cited by 38 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Localizing Functional Brain Cortices and Epileptogenic Zones With High Frequency Brain Signals
Who cites it
38 citing papers in PubMed.
- Neural Correlates of Cognitive Disengagement Syndrome Symptoms in Children: A Magnetoencephalography Study.Brain sciences · 2025Article
- Impact of interictal epileptiform discharges on brain network in self-limited epilepsy with centrotemporal spikes: A magnetoencephalography study.Brain and behavior · 2023Article
- Improved Biomagnetic Signal-To-Noise Ratio and Source Localization Using Optically Pumped Magnetometers with Synthetic Gradiometers.Brain sciences · 2023Article
- Changes in functional connectivity in newly diagnosed self-limited epilepsy with centrotemporal spikes and cognitive impairment: An MEG study.Brain and behavior · 2022Article
- Spatial and Frequency Specific Artifact Reduction in Optically Pumped Magnetometer Recordings.Journal of integrative neuroscience · 2022Article
- Altered effective connectivity in migraine patients during emotional stimuli: a multi-frequency magnetoencephalography study.The journal of headache and pain · 2022Article
- Altered Neuromagnetic Activity in Persistent Postural-Perceptual Dizziness: A Multifrequency Magnetoencephalography Study.Frontiers in human neuroscience · 2022Article
- Contributions of Magnetoencephalography to Understanding Mechanisms of Generalized Epilepsies: Blurring the Boundary Between Focal and Generalized Epilepsies?Frontiers in neurology · 2022Review
- Neuromagnetic high frequency spikes are a new and noninvasive biomarker for localization of epileptogenic zones.Seizure · 2021Article
- Delineation of epileptogenic zones with high frequency magnetic source imaging based on kurtosis and skewness.Epilepsy research · 2021Article
- Impact of Antiepileptic Drugs on Cognition and Neuromagnetic Activity in Childhood Epilepsy With Centrotemporal Spikes: A Magnetoencephalography Study.Frontiers in human neuroscience · 2021Article
- Frequency-Dependent Dynamics of Functional Connectivity Networks During Seizure Termination in Childhood Absence Epilepsy: A Magnetoencephalography Study.Frontiers in neurology · 2021Article
- Pretreatment Source Location and Functional Connectivity Network Correlated With Therapy Response in Childhood Absence Epilepsy: A Magnetoencephalography Study.Frontiers in neurology · 2021Article
- Presurgical Evaluation of Epilepsy Using Resting-State MEG Functional Connectivity.Frontiers in human neuroscience · 2021Review
- Application of High-Frequency Oscillations on Scalp EEG in Infant Spasm: A Prospective Controlled Study.Frontiers in human neuroscience · 2021Article
- The relationship between epilepsy and cognitive function in benign childhood epilepsy with centrotemporal spikes.Brain and behavior · 2020Article
- Frequency-specific changes in the default mode network in patients with cingulate gyrus epilepsy.Human brain mapping · 2020Article
- Space-Time-Frequency Multi-Sensor Analysis for Motor Cortex Localization Using Magnetoencephalography.Sensors (Basel, Switzerland) · 2020Article
- Kurtosis and skewness of high-frequency brain signals are altered in paediatric epilepsy.Brain communications · 2020Article
- Identifying the Epileptogenic Zone With the Relative Strength of High-Frequency Oscillation: A Stereoelectroencephalography Study.Frontiers in human neuroscience · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
Recent studies have revealed the importance of high-frequency brain signals (>70 Hz). One challenge of high-frequency signal analysis is that the size of time-frequency representation of high-frequency brain signals could be larger than 1 terabytes (TB), which is beyond the upper limits of a typical computer workstation's memory (<196 GB). The aim of the present study is to develop a new method to provide greater sensitivity in detecting high-frequency magnetoencephalography (MEG) signals in a single automated and versatile interface, rather than the more traditional, time-intensive visual inspection methods, which may take up to several days. To address the aim, we developed a new method, accumulated source imaging, defined as the volumetric summation of source activity over a period of time. This method analyzes signals in both low- (1~70 Hz) and high-frequency (70~200 Hz) ranges at source levels. To extract meaningful information from MEG signals at sensor space, the signals were decomposed to channel-cross-channel matrix (CxC) representing the spatiotemporal patterns of every possible sensor-pair. A new algorithm was developed and tested by calculating the optimal CxC and source location-orientation weights for volumetric source imaging, thereby minimizing multi-source interference and reducing computational cost. The new method was implemented in C/C++ and tested with MEG data recorded from clinical epilepsy patients. The results of experimental data demonstrated that accumulated source imaging could effectively summarize and visualize MEG recordings within 12.7 h by using approximately 10 GB of computer memory. In contrast to the conventional method of visually identifying multi-frequency epileptic activities that traditionally took 2-3 days and used 1-2 TB storage, the new approach can quantify epileptic abnormalities in both low- and high-frequency ranges at source levels, using much less time and computer memory.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.