Evidence map›Paper›PMID 24899896›Full record

ArticleInternational journal of dentistry2014

In vitro evaluation of leakage at implant-abutment connection of three implant systems having the same prosthetic interface using rhodamine B.

Antoine Berberi, Georges Tehini, Khaldoun Rifai, Farah Bou Nasser Eddine, Nabil El Zein, Bassam Badran, Haidar Akl

Open access · goldAbstract read
In one paragraph

Article in International journal of dentistry, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Antoine BerberiSchool of Dentistry, Lebanese University, P.O. Box 4, Hadath, Lebanon.ORCID 0000-0001-7283-3456
Georges TehiniSchool of Dentistry, Lebanese University, P.O. Box 4, Hadath, Lebanon.
Khaldoun RifaiSchool of Dentistry, Lebanese University, P.O. Box 4, Hadath, Lebanon.
Farah Bou Nasser EddineEcole Doctorale, PRASE, Lebanese University, P.O. Box 4, Hadath, Lebanon.
Nabil El ZeinEcole Doctorale, PRASE, Lebanese University, P.O. Box 4, Hadath, Lebanon.
Bassam BadranEcole Doctorale, PRASE, Lebanese University, P.O. Box 4, Hadath, Lebanon.
Haidar AklEcole Doctorale, PRASE, Lebanese University, P.O. Box 4, Hadath, Lebanon.ORCID 0000-0003-3441-321X
Lebanese University · LB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives. Hollow space between implant and abutment may act as reservoir for commensal and/or pathogenic bacteria representing a potential source of tissue inflammation. Microbial colonization of the interfacial gap may ultimately lead to infection and bone resorption. Using Rhodamine B, a sensitive fluorescent tracer dye, we aim in this study to investigate leakage at implant-abutment connection of three implant systems having the same prosthetic interface. Materials and Methods. Twenty-one implants (seven Astra Tech, seven Euroteknika, and seven Dentium) with the same prosthetic interface were connected to their original abutments, according to the manufacturers' recommendation. After determination of the inner volume of each implant systems, the kinetic quantification of leakage was evaluated for each group using Rhodamine B (10(-2) M). For each group, spectrophotometric analysis was performed to detect leakage with a fluorescence spectrophotometer at 1 h (T0) and 48 h (T1) of incubation time at room temperature. Results. Astra Tech had the highest inner volume (6.8  μ L), compared to Dentium (4  μ L) and Euroteknika (2.9  μ L). At T0 and T1, respectively, the leakage volume and percentage of each system were as follows: Astra Tech 0.043  μ L or 1.48% (SD 0.0022), 0.08  μ L or 5.56% (SD 0.0074), Euroteknika 0.09  μ L or 6.93% (SD 0.0913), 0.21  μ L or 20.55% (SD 0.0035), and Dentium 0.07  μ L or 4.6% (SD 0.0029), 0.12  μ L or 10.47% (SD 0.0072). Conclusion. The tested internal conical implant-abutment connections appear to be unable to prevent leakage. In average, Astra Tech implants showed the highest inner volume and the least leakage.

Identifiers

PMID24899896
PMCPMC4037604
OpenAlexW2102060798

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.