Evidence map›Paper›PMID 24892933›Full record

ArticlePloS one2014

Breast density assessment using a 3T MRI system: comparison among different sequences.

Alberto Tagliafico, Bianca Bignotti, Giulio Tagliafico, Davide Astengo, Lucia Martino, Sonia Airaldi, Alessio Signori, Maria Pia Sormani, Nehmat Houssami, Massimo Calabrese

Abstract readComparative Study
In one paragraph

Article in PloS one, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Alberto TagliaficoInstitute of Anatomy, Department of Experimental Medicine, University of Genova, Genova, Italy.
Bianca BignottiRadiology Department, University of Genova, Genova, Italy.
Giulio TagliaficoCNR-IMATI, Consiglio Nazionale delle Ricerche, Istituto di Matematica Applicata e Tecnologie Informatiche, Genova, Italy.
Davide AstengoRadiology Department, University of Genova, Genova, Italy.
Lucia MartinoRadiology Department, University of Genova, Genova, Italy.
Sonia AiraldiRadiology Department, University of Genova, Genova, Italy.
Alessio SignoriInstitute of Statistics, Department of Health Sciences, University of Genova, Genova, Italy.
Maria Pia SormaniInstitute of Statistics, Department of Health Sciences, University of Genova, Genova, Italy.
Nehmat HoussamiScreening and Test Evaluation Program (STEP), School of Public Health, Sydney Medical School, University of Sydney, Sydney, Australia.
Massimo CalabreseDepartment of Diagnostic Senology, Ist Istituto Nazionale per la Ricerca sul Cancro, IRCCS Azienda Ospedaliera Universitaria San Martino, Genova, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare MRI sequences for breast density measurements on a 3T MRI system using IDEAL (Iterative Decomposition of water and fat with Echo Asymmetry and Least squares estimation) as possible physiology-like reference. MATERIALS AND

methodsMRI examination was performed in 48 consecutive patients (mean age 41, years; range, 35-67 years) on a 3.0T scanner and 46 were included. All (fertile) women, were examined between days 5 and 15 of their menstrual cycle. MRI protocol included: T1-turbo spin-echo (T1-tSE), T2-turbo spin-echo (T2-tSE), VIBRANT (Volume Imaging for Breast Assessment) before and after injection of contrast media and IDEAL. Breast density was calculated with semi-automated software. Statistical analysis was performed with non-parametric tests.

resultsMean percentage of breast density calculated in each sequence was: T1-tSE = 56%; T2-tSE  = 52%; IDEAL FatOnly  = 55%; IDEAL WaterOnly  = 53%, VIBRANT = 55%. Significant differences were observed between T2-tSE and both T1-tSE (p<0.001), VIBRANT sequences (p = 0.009), T1-tSE and both IDEAL WaterOnly (p = 0.007) and IDEAL FatOnly (p = 0.047). Breast density percentage showed a positive linear correlation among different sequences: r ≥ 0.93.

conclusionsDifferences exist between MRI sequences used to assess breast density percentage. T1-weighted sequences values were similar to IDEAL sequences.

Indexed as

AdultAgedBreastFemaleHumansImage Processing, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance ImagingMiddle AgedSoftware

Identifiers

PMID24892933
PMCPMC4044003

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.