Evidence map›Paper›PMID 24887391›Full record

ArticleCritical care (London, England)2014

Detection of 'best' positive end-expiratory pressure derived from electrical impedance tomography parameters during a decremental positive end-expiratory pressure trial.

Paul Blankman, Djo Hasan, Groot Erik, Diederik Gommers

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Critical care (London, England), 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03719937 (ArtificiaL Increase in chesT Wall Elastance as an alteRnative to PRONE Positioning in Moderate-to-severe ARDS), which is not on this map. Cited by 45 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
45citing papers in PubMed, 1 pooled it
9.4field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03719937 nasuspendednot on this mapstarted 2018, after this paper: background citation

ArtificiaL Increase in chesT Wall Elastance as an alteRnative to PRONE Positioning in Moderate-to-severe ARDS: a Physiological Study The ALTERPRONE Study

TypeinterventionalSponsorCatholic University of the Sacred HeartRan2018 to 2023Enrolled15ConditionsAcute Respiratory Distress SyndromeArmsweight on the anterior chest of the patient
3 · Its place in the literature

Who cites it

45 citing papers in PubMed, 1 synthesis or guideline pooled it, 116 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Trial
  5. Trial
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Observational
  18. Observational
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors at 4 institutions in 1 country.

Paul Blankman
Djo Hasan
Groot Erik
Diederik Gommers
Erasmus MC · NLErasmus University Rotterdam · NLMaasstad Ziekenhuis · NLUniversity of Twente · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThis study compares different parameters derived from electrical impedance tomography (EIT) data to define 'best' positive end-expiratory pressure (PEEP) during a decremental PEEP trial in mechanically-ventilated patients. 'Best' PEEP is regarded as minimal lung collapse and overdistention in order to prevent ventilator-induced lung injury.

methodsA decremental PEEP trial (from 15 to 0 cm H2O PEEP in 4 steps) was performed in 12 post-cardiac surgery patients on the ICU. At each PEEP step, EIT measurements were performed and from this data the following were calculated: tidal impedance variation (TIV), regional compliance, ventilation surface area (VSA), center of ventilation (COV), regional ventilation delay (RVD index), global inhomogeneity (GI index), and intratidal gas distribution. From the latter parameter we developed the ITV index as a new homogeneity parameter. The EIT parameters were compared with dynamic compliance and the PaO2/FiO2 ratio.

resultsDynamic compliance and the PaO2/FiO2 ratio had the highest value at 10 and 15 cm H2O PEEP, respectively. TIV, regional compliance and VSA had a maximum value at 5 cm H2O PEEP for the non-dependent lung region and a maximal value at 15 cm H2O PEEP for the dependent lung region. GI index showed the lowest value at 10 cm H2O PEEP, whereas for COV and the RVD index this was at 15 cm H2O PEEP. The intratidal gas distribution showed an equal contribution of both lung regions at a specific PEEP level in each patient.

conclusionIn post-cardiac surgery patients, the ITV index was comparable with dynamic compliance to indicate 'best' PEEP. The ITV index can visualize the PEEP level at which ventilation of the non-dependent region is diminished, indicating overdistention. Additional studies should test whether application of this specific PEEP level leads to better outcome and also confirm these results in patients with acute respiratory distress syndrome.

Indexed as

AgedElectric ImpedanceFemaleHumansMaleMiddle AgedPositive-Pressure RespirationTomography

Identifiers

PMID24887391
PMCPMC4095609
OpenAlexW1982395649

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.