Predicting Plasma Glucose From Interstitial Glucose Observations Using Bayesian Methods.

Alexander Hildenbrand Hansen, Anne Katrine Duun-Henriksen, Rune Juhl, Signe Schmidt, Kirsten Nørgaard, John Bagterp Jørgensen, Henrik Madsen

Abstract read
In one paragraph

Article in Journal of diabetes science and technology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Alexander Hildenbrand HansenDTU Department of Applied Mathematics and Computer Science, Technical University of Denmark, Lyngby, Denmark alexanderhhansen@gmail.com.
Anne Katrine Duun-HenriksenDTU Department of Applied Mathematics and Computer Science, Technical University of Denmark, Lyngby, Denmark.
Rune JuhlDTU Department of Applied Mathematics and Computer Science, Technical University of Denmark, Lyngby, Denmark.
Signe SchmidtDepartment of Endocrinology, Hvidovre University Hospital, Hvidovre, Denmark.
Kirsten NørgaardDepartment of Endocrinology, Hvidovre University Hospital, Hvidovre, Denmark.
John Bagterp JørgensenDTU Department of Applied Mathematics and Computer Science, Technical University of Denmark, Lyngby, Denmark.
Henrik MadsenDTU Department of Applied Mathematics and Computer Science, Technical University of Denmark, Lyngby, Denmark.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

One way of constructing a control algorithm for an artificial pancreas is to identify a model capable of predicting plasma glucose (PG) from interstitial glucose (IG) observations. Stochastic differential equations (SDEs) make it possible to account both for the unknown influence of the continuous glucose monitor (CGM) and for unknown physiological influences. Combined with prior knowledge about the measurement devices, this approach can be used to obtain a robust predictive model. A stochastic-differential-equation-based gray box (SDE-GB) model is formulated on the basis of an identifiable physiological model of the glucoregulatory system for type 1 diabetes mellitus (T1DM) patients. A Bayesian method is used to estimate robust parameters from clinical data. The models are then used to predict PG from IG observations from 2 separate study occasions on the same patient. First, all statistically significant diffusion terms of the model are identified using likelihood ratio tests, yielding inclusion of [Formula: see text], [Formula: see text], and [Formula: see text]. Second, estimates using maximum likelihood are obtained, but prediction capability is poor. Finally a Bayesian method is implemented. Using this method the identified models are able to predict PG using only IG observations. These predictions are assessed visually. We are also able to validate these estimates on a separate data set from the same patient. This study shows that SDE-GBs and a Bayesian method can be used to identify a reliable model for prediction of PG using IG observations obtained with a CGM. The model could eventually be used in an artificial pancreas.

Indexed as

Bayesian methodsPG-IG dynamicsplasma glucose dynamicsstochastic differential equationsstochastic gray-box modelingtype 1 diabetes mellitus