Evidence map›Paper›PMID 24876544›Full record

ArticleJournal of diabetes science and technology2014

Validity and Reliability of a Glucometer Against Industry Reference Standards.

Amanda J Salacinski, Micah Alford, Kathryn Drevets, Sarah Hart, Brian E Hunt

Abstract read
In one paragraph

Article in Journal of diabetes science and technology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Advances in laboratory medicine · 2024
    Article
  7. Comparative Study Between Blood Glucose Meters in a Maternity Center.Women's health reports (New Rochelle, N.Y.) · 2024
    Article
  8. Review
  9. Article
  10. Article
  11. Glucose meters: What's the laboratory reference glucose?Journal of medical biochemistry · 2020
    Article
  12. Article
  13. Accuracy of 5 Point-of-Care Glucometers in C57BL/6J Mice.Journal of the American Association for Laboratory Animal Science : JAALAS · 2018
    Article
  14. Article
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Amanda J SalacinskiDepartment of Kinesiology and Physical Education, Northern Illinois University, DeKalb, IL, USA asalacinski@niu.edu.
Micah AlfordDepartment of Applied Health Science, Wheaton College, Wheaton, IL, USA.
Kathryn DrevetsDepartment of Applied Health Science, Wheaton College, Wheaton, IL, USA.
Sarah HartDepartment of Applied Health Science, Wheaton College, Wheaton, IL, USA.
Brian E HuntDepartment of Applied Health Science, Wheaton College, Wheaton, IL, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

As an appealing alternative to reference glucose analyzers, portable glucometers are recommended for self-monitoring at home, in the field, and in research settings. The purpose was to characterize the accuracy and precision, and bias of glucometers in biomedical research. Fifteen young (20-36 years; mean = 24.5), moderately to highly active men (n = 10) and women (n = 5), defined by exercising 2 to 3 times a week for the past 6 months, were given an oral glucose tolerance test (OGTT) after an overnight fast. Participants ingested 50, 75, or 150 grams of glucose over a 5-minute period. The glucometer was compared to a reference instrument. The glucometer had 39% of values within 15% of measurements made using the reference instrument ranging from 45.05 to 169.37 mg/dl. There was both a proportional (-0.45 to -0.39) and small fixed (5.06 and 0.90 mg/dl) bias. Results of the present study suggest that the glucometer provided poor validity and reliability results compared to the results provided by the reference laboratory analyzer. The portable glucometers should be used for patient management, but not for diagnosis, treatment, or research purposes.

Indexed as

accuracybiasoral glucose tolerance testreproducibility

Identifiers

PMID24876544
PMCPMC4454112

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.