Evidence map›Paper›PMID 24876538›Full record

ArticleJournal of diabetes science and technology2014

Accuracy of a Novel Noninvasive Multisensor Technology to Estimate Glucose in Diabetic Subjects During Dynamic Conditions.

Sandra I Sobel, Peter J Chomentowski, Nisarg Vyas, David Andre, Frederico G S Toledo

Open access · bronzeAbstract read
In one paragraph

Article in Journal of diabetes science and technology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
1.1field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 25 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Analysis of wearable time series data in endocrine and metabolic research.Current opinion in endocrine and metabolic research · 2022
    Review
  6. Article
  7. Review
  8. Disruption in the diabetic device care market.Medical devices (Auckland, N.Z.) · 2018
    Review
  9. Review
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Sandra I SobelDiv. Endocrinology and Metabolism, University of Pittsburgh, Pittsburgh, PA, USA.
Peter J ChomentowskiDiv. Endocrinology and Metabolism, University of Pittsburgh, Pittsburgh, PA, USA.
Nisarg VyasBodyMedia, Inc, Pittsburgh, PA, USA.
David AndreBodyMedia, Inc, Pittsburgh, PA, USA.
Frederico G S ToledoDiv. Endocrinology and Metabolism, University of Pittsburgh, Pittsburgh, PA, USA tolefs@upmc.edu.
University of Pittsburgh · USHealthMedia (United States) · US

Funding

UNIVERSITY OF PITTSBURGH CLINICAL AND TRANSLATIONAL SCIENCE INSTITUTE: BPCAUL1RR024153 · NCRR · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI REIS, STEVEN E · 2006 to 2011
$73.9M
NCRR NIH HHS UL1 RR024153
6 · The paper itself

Abstract

The purpose of this study was to determine whether an approach of multisensor technology with integrated data analysis in an armband system (SenseWear® Pro Armband, SWA) can provide estimates of plasma glucose concentration in diabetes. In all, 41 subjects with diabetes participated. On day 1 subjects underwent an oral glucose tolerance test (OGTT) and on day 2 a 60-minute treadmill test (TT). SWA plasma glucose estimates were compared against reference peripheral venous glucose concentrations. A continuous glucose monitoring device (CGM) was also placed on each subject to serve as a reference for clinical comparison. Pearson coefficient, Clarke error grid (CEG), and mean absolute relative difference (MARD) analyses were used to compare the performance of plasma glucose estimation. There were significant correlations between plasma glucose concentrations estimated by the SWA and the reference plasma glucose concentration during the OGTT (r = .65, P < .05) and the TT (r = .91, P < .05). CEG analysis revealed that during the OGTT, 93% of plasma glucose concentration readings were in the clinically acceptable zone A+B for the SWA and 95% for the CGM. During the TT, the SWA had 96% of readings in zone A+B, compared to 97% for the CGM. During OGTTs, MARDs for the SWA and CGM were 26% and 18%, respectively. During TTs, MARDs were 16% and 12%, respectively. Plasma glucose concentration estimation by the SWA's noninvasive multisensor approach appears to be feasible and its performance in estimating glucose approaches that of a CGM. The success of this pilot study suggests that multisensor technology holds promising potential for the development of a wearable, noninvasive, painless glucose monitor.

Indexed as

accuracycontinuous glucose monitornoninvasive glucose monitoringself-monitoring of blood glucose

Identifiers

PMID24876538
PMCPMC4454109
OpenAlexW2150092204

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.