ArticleJournal of controlled release : official journal of the Controlled Release Society2014
A rapamycin-releasing perivascular polymeric sheath produces highly effective inhibition of intimal hyperplasia.
Article in Journal of controlled release : official journal of the Controlled Release Society, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 36 citations in OpenAlex.
- Nano-based perivascular intervention sustains a nine-month long-term suppression of intimal hyperplasia in vein grafts.Bioactive materials · 2025Article
- Sirolimus-Embedded Silk Microneedle Wrap to Prevent Neointimal Hyperplasia in Vein Graft Model.International journal of molecular sciences · 2023Article
- Periadventitial Delivery of Simvastatin-Loaded Microparticles Attenuate Venous Neointimal Hyperplasia Associated With Arteriovenous Fistula.Journal of the American Heart Association · 2020Article
- Perivascular delivery of resolvin D1 inhibits neointimal hyperplasia in a rabbit vein graft model.Journal of vascular surgery · 2018Article
- Unimolecular Micelle-Based Hybrid System for Perivascular Drug Delivery Produces Long-Term Efficacy for Neointima Attenuation in Rats.Biomacromolecules · 2017Article
- A Biodegradable Microneedle Cuff for Comparison of Drug Effects through Perivascular Delivery to Balloon-Injured Arteries.Polymers · 2017Article
- Restenosis Inhibition and Re-differentiation of TGFβ/Smad3-activated Smooth Muscle Cells by Resveratrol.Scientific reports · 2017Article
- Unidirectional and sustained delivery of the proresolving lipid mediator resolvin D1 from a biodegradable thin film device.Journal of biomedical materials research. Part A · 2017Article
- Perivascular delivery of resolvin D1 inhibits neointimal hyperplasia in a rat model of arterial injury.Journal of vascular surgery · 2017Article
- Biomaterial-Based Approaches to Address Vein Graft and Hemodialysis Access Failures.Macromolecular rapid communications · 2016Review
- Periadventitial drug delivery for the prevention of intimal hyperplasia following open surgery.Journal of controlled release : official journal of the Controlled Release Society · 2016Review
- Preparation and experimental research into retrievable rapamycin- and heparin-coated vena cava filters: a pilot study.Journal of thrombosis and thrombolysis · 2016Article
- Immunosuppressive nano-therapeutic micelles downregulate endothelial cell inflammation and immunogenicity.RSC advances · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
Abstract
Intimal hyperplasia produces restenosis (re-narrowing) of the vessel lumen following vascular intervention. Drugs that inhibit intimal hyperplasia have been developed, however there is currently no clinical method of perivascular drug-delivery to prevent restenosis following open surgical procedures. Here we report a poly(ε-caprolactone) (PCL) sheath that is highly effective in preventing intimal hyperplasia through perivascular delivery of rapamycin. We first screened a series of bioresorbable polymers, i.e., poly(lactide-co-glycolide) (PLGA), poly(lactic acid) (PLLA), PCL, and their blends, to identify desired release kinetics and sheath physical properties. Both PLGA and PLLA sheaths produced minimal (<30%) rapamycin release within 50days in PBS buffer. In contrast, PCL sheaths exhibited more rapid and near-linear release kinetics, as well as durable integrity (>90days) as evidenced in both scanning electron microscopy and subcutaneous embedding experiments. Moreover, a PCL sheath deployed around balloon-injured rat carotid arteries was associated with a minimum rate of thrombosis compared to PLGA and PLLA. Morphometric analysis and immunohistochemistry revealed that rapamycin-loaded perivascular PCL sheaths produced pronounced (85%) inhibition of intimal hyperplasia (0.15±0.05 vs 1.01±0.16), without impairment of the luminal endothelium, the vessel's anti-thrombotic layer. Our data collectively show that a rapamycin-loaded PCL delivery system produces substantial mitigation of neointima, likely due to its favorable physical properties leading to a stable yet flexible perivascular sheath and steady and prolonged release kinetics. Thus, a PCL sheath may provide useful scaffolding for devising effective perivascular drug delivery particularly suited for preventing restenosis following open vascular surgery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials