ArticleAnnals of coloproctology2014
Niti CAR 27 Versus a Conventional End-to-End Anastomosis Stapler in a Laparoscopic Anterior Resection for Sigmoid Colon Cancer.
Article in Annals of coloproctology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 1 synthesis or guideline pooled it, 7 citations in OpenAlex.
- A systematic analysis of controlled clinical trials using the NiTi CAR™ compression ring in colorectal anastomoses.Techniques in coloproctology · 2017Pooled it
- Systematic Review and Meta-Analysis on Colorectal Anastomotic Techniques.Therapeutics and clinical risk management · 2022Review
- Efficacy and safety of a NiTi CAR 27 compression ring for end-to-end anastomosis compared with conventional staplers: A real-world analysis in Chinese colorectal cancer patients.Clinics (Sao Paulo, Brazil) · 2016Article
- The new stapler device is good, but needs more evaluation.Annals of coloproctology · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe Niti CAR 27 (ColonRing) uses compression to create an anastomosis. This study aimed to investigate the safety and the effectiveness of the anastomosis created with the Niti CAR 27 in a laparoscopic anterior resection for sigmoid colon cancer.
methodsIn a single-center study, 157 consecutive patients who received an operation between March 2010 and December 2011 were retrospectively assessed. The Niti CAR 27 (CAR group, 63 patients) colorectal anastomoses were compared with the conventional double-stapled (CDS group, 94 patients) colorectal anastomoses. Intraoperative, immediate postoperative and 6-month follow-up data were recorded.
resultsThere were no statistically significant differences between the two groups in terms of age, gender, tumor location and other clinical characteristics. One patient (1.6%) in the CAR group and 2 patients (2.1%) in the CDS group experienced complications of anastomotic leakage (P = 0.647). These three patients underwent a diverting loop ileostomy. There were 2 cases (2.1%) of bleeding at the anastomosis site in the CDS group. All patients underwent a follow-up colonoscopy (median, 6 months). One patient in the CAR group experienced anastomotic stricture (1.6% vs. 0%; P = 0.401). This complication was solved by using balloon dilatation.
conclusionAnastomosis using the Niti CAR 27 device in a laparoscopic anterior resection for sigmoid colon cancer is safe and feasible. Its use is equivalent to that of the conventional double-stapler.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.