ArticleNMR in biomedicine2014
DYNAmic Multi-coIl TEchnique (DYNAMITE) shimming of the rat brain at 11.7 T.
Article in NMR in biomedicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 37 citations in OpenAlex.
- Field-Based Spatial Self-Registration of Multicoil Hardware for BMagnetic resonance in medicine · 2026Article
- Mastering preclinical proton and deuterium-based fast MRSI in the brain: from setup to execution.Magma (New York, N.Y.) · 2026Review
- Localized Shims Enable Low-Field Simultaneous Multinuclear NMR Spectroscopy.Analytical chemistry · 2024Article
- High-quality lipid suppression and B0 shimming for human brainNeuroImage · 2024Article
- Advancements in MR hardware systems and magnetic field control: BPsychoradiology · 2024Review
- Design and realization of a multi-coil array for BMagnetic resonance in medicine · 2023Article
- Concerted roles of LRRTM1 and SynCAM 1 in organizing prefrontal cortex synapses and cognitive functions.Nature communications · 2023Article
- Analysis of coil element distribution and dimension for matrix gradient coils.Magma (New York, N.Y.) · 2022Article
- Optimization of a quadrature birdcage coil for functional imaging of squirrel monkey brain at 9.4T.Magnetic resonance imaging · 2021Article
- Dynamic multicoil technique (DYNAMITE) MRI on human brain.Magnetic resonance in medicine · 2020Article
- Article
- Spontaneous activity forms a foundation for odor-evoked activation maps in the rat olfactory bulb.NeuroImage · 2018Article
- The public multi-coil information (PUMCIN) policy.Magnetic resonance in medicine · 2017Article
- BAnalytical biochemistry · 2017Review
- Quantitative β mapping for calibrated fMRI.NeuroImage · 2016Article
- Comparison of glomerular activity patterns by fMRI and wide-field calcium imaging: Implications for principles underlying odor mapping.NeuroImage · 2016Article
- Article
- Multi-slice MRI with the dynamic multi-coil technique.NMR in biomedicine · 2015Article
- Dynamic multi-coil technique (DYNAMITE) shimming for echo-planar imaging of the human brain at 7 Tesla.NeuroImage · 2015Article
- DYNAmic Multi-coIl TEchnique (DYNAMITE) shimming of the rat brain at 11.7 T.NMR in biomedicine · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 2 countries.
Funding
Abstract
The in vivo rat model is a workhorse in neuroscience research, preclinical studies and drug development. A repertoire of MR tools has been developed for its investigation; however, high levels of B0 magnetic field homogeneity are required for meaningful results. The homogenization of magnetic fields in the rat brain, i.e. shimming, is a difficult task because of a multitude of complex, susceptibility-induced field distortions. Conventional shimming with spherical harmonic (SH) functions is capable of compensating for shallow field distortions in limited areas, e.g. in the cortex, but performs poorly in difficult-to-shim subcortical structures or for the entire brain. Based on the recently introduced multi-coil approach for magnetic field modeling, the DYNAmic Multi-coIl TEchnique (DYNAMITE) is introduced for magnetic field shimming of the in vivo rat brain and its benefits for gradient-echo echo-planar imaging (EPI) are demonstrated. An integrated multi-coil/radiofrequency (MC/RF) system comprising 48 individual localized DC coils for B0 shimming and a surface transceive RF coil has been developed that allows MR investigations of the anesthetized rat brain in vivo. DYNAMITE shimming with this MC/RF set-up is shown to reduce the B0 standard deviation to a third of that achieved with current shim technology employing static first- through third-order SH shapes. The EPI signal over the rat brain increased by 31%, and a 24% gain in usable EPI voxels could be realized. DYNAMITE shimming is expected to critically benefit a wide range of preclinical and neuroscientific MR research. Improved magnetic field homogeneity, together with the achievable large brain coverage of this method, will be crucial when signal pathways, cortical circuitry or the brain's default network are studied. Together with the efficiency gains of MC-based shimming compared with SH approaches demonstrated recently, DYNAMITE shimming has the potential to replace conventional SH shim systems in small-bore animal scanners.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.