Evidence map›Paper›PMID 24838737›Full record

ArticleEuropean radiology2014

Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience.

Fabian Morsbach, Sonja Gordic, Lotus Desbiolles, Daniela Husarik, Thomas Frauenfelder, Bernhard Schmidt, Thomas Allmendinger, Simon Wildermuth, Hatem Alkadhi, Sebastian Leschka

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Dual-source photon-counting CT: consistency in spectral results at different acquisition modes and heart rates.Proceedings of SPIE--the International Society for Optical Engineering · 2022
    Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Advances in myocardial CT perfusion imaging technology.American journal of translational research · 2016
    Review
  18. Article
  19. Chest pain: coronary CT in the ER.The British journal of radiology · 2016
    Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Fabian MorsbachInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
Sonja Gordic
Lotus Desbiolles
Daniela Husarik
Thomas Frauenfelder
Bernhard Schmidt
Thomas Allmendinger
Simon Wildermuth
Hatem Alkadhi
Sebastian Leschka

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo evaluate image quality, maximal heart rate allowing for diagnostic imaging, and radiation dose of turbo high-pitch dual-source coronary computed tomographic angiography (CCTA).

methodsFirst, a cardiac motion phantom simulating heart rates (HRs) from 60-90 bpm in 5-bpm steps was examined on a third-generation dual-source 192-slice CT (prospective ECG-triggering, pitch 3.2; rotation time, 250 ms). Subjective image quality regarding the presence of motion artefacts was interpreted by two readers on a four-point scale (1, excellent; 4, non-diagnostic). Objective image quality was assessed by calculating distortion vectors. Thereafter, 20 consecutive patients (median, 50 years) undergoing clinically indicated CCTA were included.

resultsIn the phantom study, image quality was rated diagnostic up to the HR75 bpm, with object distortion being 1 mm or less. Distortion increased above 1 mm at HR of 80-90 bpm. Patients had a mean HR of 66 bpm (47-78 bpm). Coronary segments were of diagnostic image quality for all patients with HR up to 73 bpm. Average effective radiation dose in patients was 0.6 ± 0.3 mSv.

conclusionsOur combined phantom and patient study indicates that CCTA with turbo high-pitch third-generation dual-source 192-slice CT can be performed at HR up to 75 bpm while maintaining diagnostic image quality, being associated with an average radiation dose of 0.6 mSv. KEY POINTS: • CCTA is feasible with the turbo high-pitch mode. • Turbo high-pitch CCTA provides diagnostic image quality up to 73 bpm. • The radiation dose of high-pitch CCTA is 0.6 mSv on average.

Indexed as

ArtifactsImaging, Three-DimensionalPhantoms, ImagingAdultAgedAged, 80 and overCoronary AngiographyCoronary Artery DiseaseFemaleHeart RateHumansMaleMiddle AgedMultidetector Computed TomographyProspective StudiesRadiation Dosage

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.