Evidence map›Paper›PMID 24821391›Full record

ArticleInternational journal of molecular medicine2014

Evaluation of parameters in mixed male DNA profiles for the Identifiler® multiplex system.

Na Hu, Bin Cong, Tao Gao, Rong Hu, Yi Chen, Hui Tang, Luyan Xue, Shujin Li, Chunling Ma

Open access · hybridAbstract read
In one paragraph

Article in International journal of molecular medicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Na HuHebei Key Laboratory of Forensic Medicine, Department of Forensic Medicine, Hebei Medical University, Shijiazhuang, Hebei 050017, P.R. China.
Bin CongHebei Key Laboratory of Forensic Medicine, Department of Forensic Medicine, Hebei Medical University, Shijiazhuang, Hebei 050017, P.R. China.
Tao GaoInstitute of Statistics, Renmin University of China, Beijing 100872, P.R. China.
Rong HuHebei Key Laboratory of Forensic Medicine, Department of Forensic Medicine, Hebei Medical University, Shijiazhuang, Hebei 050017, P.R. China.
Yi ChenInstitute of Statistics, Renmin University of China, Beijing 100872, P.R. China.
Hui TangDNA Laboratory, Forensic Science Service of Beijing Public Security Bureau, Beijing 100085, P.R. China.
Luyan XueDNA Laboratory, Forensic Science Service of Beijing Public Security Bureau, Beijing 100085, P.R. China.
Shujin LiHebei Key Laboratory of Forensic Medicine, Department of Forensic Medicine, Hebei Medical University, Shijiazhuang, Hebei 050017, P.R. China.
Chunling MaHebei Key Laboratory of Forensic Medicine, Department of Forensic Medicine, Hebei Medical University, Shijiazhuang, Hebei 050017, P.R. China.
Hebei Medical University · CNRenmin University of China · CNShanghai Public Security Bureau · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The analysis of complex DNA mixtures is challenging for forensic DNA testing. Accurate and sensitive methods for profiling these samples are urgently required. In this study, we developed 11 groups of mixed male DNA samples (n=297) with scientific validation of D‑value [>95% of D‑values ≤0.1 with average peak height (APH) of the active alleles ≤2,500 rfu]. A strong linear correlation was detected between the peak height (PH) and peak area (PA) in the curve fit using the least squares method (P<2e-16). The Kruskal-Wallis rank-sum test revealed significant differences in the heterozygote balance ratio (H(b)) at 16 short tandem repeat (STR) loci (P=0.0063) and 9 mixed gradients (P=0.02257). Locally weighted regression fitting of APH and Hb (inflection point at APH = 1,250 rfu) showed 92.74% of H(b) >0.6 with the APH ≥1,250. The variation of H(b) distribution in the different STR loci suggested the different forensic efficiencies of these loci. Allelic drop-out (ADO) correlated with the APH and mixed gradient. All ADOs had an APH of <1,000 rfu, and the number of ADO increased when the APH of mixed DNA profiles gradually decreased. These results strongly suggest that calibration parameters should be introduced to correct the deviation in the APH at each STR locus during the analysis of mixed DNA samples.

Indexed as

Genetic LociMicrosatellite RepeatsAllelesCalibrationDNAForensic GeneticsHeterozygoteHumansLeast-Squares AnalysisMaleMultiplex Polymerase Chain ReactionDNA

Identifiers

PMID24821391
PMCPMC4072395
OpenAlexW2147535572

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.