Evidence map›Paper›PMID 24818794›Full record

ArticleJournal of biomechanics2014

Motor adaptation to prosthetic cycling in people with trans-tibial amputation.

W Lee Childers, Boris I Prilutsky, Robert J Gregor

Abstract read
In one paragraph

Article in Journal of biomechanics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Postural sway and motor control in trans-tibial amputees as assessed by electroencephalography during eight balance training tasks.Medical science monitor : international medical journal of experimental and clinical research · 2014
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

W Lee ChildersDepartment of Prosthetics and Orthotics; Montgomery, College of Health Sciences, Alabama State University, Montgomery, AL, USA. Electronic address: lchilders@alasu.edu.
Boris I PrilutskySchool of Applied Physiology, Center for Human Movement Studies, Georgia Institute of Technology, Atlanta, GA, USA.
Robert J GregorSchool of Applied Physiology, Center for Human Movement Studies, Georgia Institute of Technology, Atlanta, GA, USA; Division of Biokinesiology and Physical Therapy, University of Southern California, Los Angeles, CA, USA.

Funding

Training Movement Scientists: Focus on Prosthetics and OrthoticsT32HD055180 · NICHD · GEORGIA INSTITUTE OF TECHNOLOGY · PI NICHOLS, T. RICHARD · 2008 to 2017
$1.9M
NICHD NIH HHS T32 HD055180NICHD NIH HHS T32HD055180-01A1
6 · The paper itself

Abstract

The neuromusculoskeletal system interacts with the external environment via end-segments, e.g. feet. A person with trans-tibial amputation (TTAmp) has lost a foot and ankle; hence the residuum with prosthesis becomes the new end-segment. We investigated changes in kinetics and muscle activity in TTAmps during cycling with this altered interface with the environment. Nine unilateral TTAmps and nine subjects without amputation (NoAmp) pedaled at a constant torque of 15 Nm and a constant cadence of 90 rpm (~150 watts). Pedal forces and limb kinematics were used to calculate resultant joint moments. Electromyographic activity was recorded to determine its magnitude and timing. Biomechanical and EMG variables of the amputated limb were compared to those of the TTAmp sound limb and to the dominant limb in the NoAmp group using a one-way ANOVA. Results showed maximum angular displacement between the residuum and prosthesis was 4.8±1.8 deg. The amputated limb compared to sound limb and NoAmp group produced lower extensor moments averaged over the cycle about the ankle (13±2.3, 20±5.7, and 19±5.3 Nm, respectfully) and knee (8.4±5.0, 15±4.5, and 12.7±5.9 Nm, respectfully) (p<0.05). Gastrocnemius and rectus femoris peak activity in the TTAmps shifted to later in the crank cycle (by 36° and 75°, respectfully; p<0.05). These data suggest gastrocnemius was utilized as a one-joint knee flexor in combination with rectus femoris for prosthetic socket control and highlight prosthetic control as an interaction between the residuum, prosthesis and external environment.

Indexed as

Artificial LimbsBicyclingAdaptation, PhysiologicalAdultAmputation, SurgicalAnkle JointBiomechanical PhenomenaElectromyographyFootHumansKineticsKnee JointMotor SkillsMuscle, SkeletalTibiaTorqueBelow knee amputationBicyclingMotor controlProstheticsSport biomechanics

Identifiers

PMID24818794
PMCPMC4076118

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked