Evidence map›Paper›PMID 24817800›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2013

Dose Reduction in Fluoroscopic Interventions Using a Combination of a Region of Interest (ROI) X-Ray Attenuator and Spatially-Different, Temporally-Variable Temporal Filtering.

S N Swetadri Vasan, Liza Pope, Ciprian N Ionita, A H Titus, D R Bednarek, S Rudin

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.5field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Organ and effective dose reduction for region-of-interest (ROI) CBCT and fluoroscopy.Proceedings of SPIE--the International Society for Optical Engineering · 2017
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

S N Swetadri VasanDepartment of Electrical Engineering, University at Buffalo ; Toshiba Stroke and Vascular Research Center, University at Buffalo.
Liza PopeToshiba Stroke and Vascular Research Center, University at Buffalo.
Ciprian N IonitaToshiba Stroke and Vascular Research Center, University at Buffalo.
A H TitusDepartment of Electrical Engineering, University at Buffalo ; Toshiba Stroke and Vascular Research Center, University at Buffalo.
D R BednarekToshiba Stroke and Vascular Research Center, University at Buffalo.
S RudinDepartment of Electrical Engineering, University at Buffalo ; Toshiba Stroke and Vascular Research Center, University at Buffalo.
Toshiba (United States) · USToshiba (Japan) · JP

Funding

Micro-Radiographic Imager for Neuroovascular InterventionsR01EB002873 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2003 to 2015
$5.6M
Solid State X-ray Image Intensifier DevelopmentR01EB008425 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2008 to 2011
$2.6M
NIBIB NIH HHS R01 EB002873NIBIB NIH HHS R01 EB008425
6 · The paper itself

Abstract

A novel dose reduction technique for fluoroscopic interventions involving a combination of a material x-ray region of interest (ROI) attenuator and spatially different, temporally variable ROI temporal recursive filter, was used to guide the catheter to the ROI in three live animal studies, two involving rabbits and one involving a sheep. In the two rabbit studies presented, a catheter was guided to the entrance of the carotid artery. With the added ROI attenuator the image under the high attenuation region is very noisy. By using temporal filtering with a filter weight of 0.6 on previous frames, the noise is reduced. In the sheep study the catheter was guided to the descending aorta of the animal. The sheep offered a relatively higher attenuation to the incident x-rays and thus a higher temporal filter weight of 0.8 on previous frames was used during the procedure to reduce the noise to levels acceptable by the interventionalist. The image sequences from both studies show that significant dose reduction of 5-6 times can be achieved with acceptable image quality outside the ROI by using the above mentioned technique. Even though the temporal filter weighting outside the ROI is higher, the consequent lag does not prevent perception of catheter movement.

Identifiers

PMID24817800
PMCPMC4013118
OpenAlexW2009279283

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked