Evidence map›Paper›PMID 24805068›Full record

ArticleJournal of biomechanical engineering2014

Ultrasound assessment of ex vivo lung tissue properties using a fluid-filled negative pressure bath.

Sarah Duenwald-Kuehl, Melissa L Bates, Sonia Y Cortes, Marlowe W Eldridge, Ray Vanderby

Open access · greenAbstract read
In one paragraph

Article in Journal of biomechanical engineering, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 85% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Sarah Duenwald-Kuehl
Melissa L Bates
Sonia Y Cortes
Marlowe W Eldridge
Ray Vanderby
University of Wisconsin–Madison · US

Funding

Comprehensive Characterization of Intrapulmonary Arteriovenous Pathways in HealthR01HL086897 · NHLBI · UNIVERSITY OF WISCONSIN-MADISON · PI ELDRIDGE, MARLOWE · 2008 to 2012
$1.8M
Modulation of the Immune System to Improve Ligament/Ligament Graft HealingR01AR059916 · NIAMS · UNIVERSITY OF WISCONSIN-MADISON · PI MURPHY, WILLIAM L., VANDERBY, RAY · 2010 to 2014
$1.4M
NHLBI NIH HHS 5R01HL086897NHLBI NIH HHS R01 HL086897NIAMS NIH HHS 5R01AR059916NIAMS NIH HHS R01 AR059916PHS HHS 5T32L007654
6 · The paper itself

Abstract

A relationship between tendon stress and strain and ultrasonic echo intensity has previously been defined in tendons, demonstrating a correlation between tissue stiffness and echo intensity. An analogous relationship between volume-dependent pressure changes and echo intensity changes in inflating lungs would indicate a correlation between lung compliance and echo intensity. Lung compliance is an important metric to diagnose pathologies which affect lung tissue mechanics, such as emphysema and cystic fibrosis. The goal of this study is to demonstrate a correlation between ultrasound echo intensity and lung tissue mechanics in an ex vivo model using a fluid-filled negative pressure bath design which provides a controlled environment for ultrasonic and mechanical measurements. Lungs from 4 male Sprague-Dawley rats were removed and mechanically tested via inflation and deflation in a negative pressure chamber filled with hetastarch. Specific volumes (1, 2, 3, and 4 mL) were removed from the chamber using a syringe to create negative pressure, which resulted in lung inflation. A pressure transducer recorded the pressure around the lungs. From these data, lung compliance was calculated. Ultrasound images were captured through the chamber wall to determine echo intensity (grayscale brightness in the ultrasound image), which was then related to mechanical parameters. Ultrasound images of the lung were successfully captured through the chamber wall with sufficient resolution to deduce echo intensity changes in the lung tissue. Echo intensity (0-255 scale) increased with volumetric changes (18.4 ± 5.5, 22.6 ± 5.1, 26.1 ± 7.5, and 42.9 ± 19.5 for volumetric changes of 1, 2, 3, and 4 mL) in a pattern similar to pressure (-6.8 ± 1.7, -6.8 ± 1.4, -9.4 ± 0.7, and -16.9 ± 6.8 cm H2O for 1, 2, 3, and 4 mL), reflecting changes in lung compliance. Measured rat lung tissue compliance was comparable to reported values from ex vivo lungs (0.178 ± 0.067, 0.378 ± 0.051, 0.427 ± 0.062, and 0.350 ± 0.160 mL/cm H20 for 1, 2, 3, and 4 mL), supporting proof of concept for the experimental method. Changes in echo intensity reflected changes in lung compliance in this ex vivo model, thus, supporting our hypothesis that the stiffness-related changes in echo intensity originally seen in tendon can be similarly detected in lung tissue. The presented ultrasound-based methods allowed measurement of local lung tissue compliance in a controlled environment, however, the methods could be expanded to facilitate both ex vivo and in vivo studies.

Indexed as

PressureAnimalsLungLung ComplianceMaleRatsRats, Sprague-DawleyStress, MechanicalTendonsUltrasonography

Identifiers

PMID24805068
PMCPMC4098756
OpenAlexW2129972718

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.