ArticleJournal of anaesthesiology, clinical pharmacology2014
Comparison of I-gel with proseal LMA in adult patients undergoing elective surgical procedures under general anesthesia without paralysis: A prospective randomized study.
Article in Journal of anaesthesiology, clinical pharmacology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 4 syntheses or guidelines pooled it, 19 citations in OpenAlex.
- Choice of supraglottic airway devices: a network meta-analysis of randomised controlled trials.British journal of anaesthesia · 2024Pooled it
- Contrast of oropharyngeal leak pressure and clinical performance of I-gel™ and LMA ProSeal™ in patients: A meta-analysis.PloS one · 2022Pooled it
- Comparison of oropharyngeal leak pressure and clinical performance of LMA ProSeal™ and i-gel® in adults: Meta-analysis and systematic review.The Journal of international medical research · 2016Pooled it
- Comparison of the i-gel and the laryngeal mask airway proseal during general anesthesia: a systematic review and meta-analysis.PloS one · 2015Pooled it
- Randomized Assessment of Airway Seal Pressure and Insertion Dynamics: I-gel versus Laryngeal Mask Airway Protector in Adult Difficult Airway Simulation in Patients Undergoing Laparoscopic Surgeries.Annals of African medicine · 2026Trial
- Comparison between the Baska MaskTurkish journal of anaesthesiology and reanimation · 2019Article
- A randomised controlled trial comparing ProSeal laryngeal mask airway, i-gel and Laryngeal Tube Suction-D under general anaesthesia for elective surgical patients requiring controlled ventilation.Indian journal of anaesthesia · 2017Article
- Comparison of I-gel with Classic Laryngeal Mask Airway Regarding the Ease of Use and Clinical Performance.Turkish journal of anaesthesiology and reanimation · 2015Article
- Comparison of the Disposable Streamlined Liner of the Pharynx Airway and the Disposable I-gel in Anaesthetized, Paralyzed Adults: A Randomized Prospective Study.Anesthesiology research and practice · 2015Article
- Comparison of Two Supraglottic Airway Devices: I-gel Airway and ProSeal Laryngeal Mask Airway Following Digital Insertion in Nonparalyzed Anesthetized Patients.Anesthesia, essays and researchesArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundWe compared i-gel and ProSeal laryngeal mask airway (PLMA) regarding time taken for insertion, effective seal, fiberoptic view of larynx, ease of Ryle's tube insertion, and postoperative sore throat assessment. MATERIALS AND
methodsIn a prospective, randomized manner, 48 adult patients of American Society of Anesthesiologists I-II of either gender between 18 and 60 years presenting for a short surgical procedure were assigned to undergo surgery under general anesthesia on spontaneous ventilation using either the i-gel or PLMA. An experienced nonblinded anesthesiologist inserted appropriate sized i-gel or PLMA in patients using standard insertion technique and assessed the intraoperative findings of the study regarding regarding time taken for respective device insertion, effective seal, fiberoptic view of larynx, ease of Ryle's tube insertion, and postoperative sore throat assessment. Postoperative assessment of sore throat was done by blinded anesthesia resident.
resultsThe time required for insertion of i-gel was lesser (21.98 ± 5.42 and 30.60 ± 8.51 s in Group I and Group P, respectively; P = 0.001). Numbers of attempts for successful insertions were comparable and in majority, device was inserted in first attempt. The mean airway leak pressures were comparable. However, there were more number of patients in Group P who had airway leak pressure >20 cm H2O. The fiberoptic view of glottis, ease of Ryle's tube insertion, and incidence of complications were comparable.
conclusionTime required for successful insertion of i-gel was less in adult patients undergoing short surgical procedure under general anesthesia on spontaneous ventilation. Patients with airway leak pressure >20 cm H2O were more in PLMA group which indicates its better suitability for controlled ventilation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials