Evidence map›Paper›PMID 24800183›Full record

ArticleAdvanced biomedical research2014

Comparative evaluation of three different methods for HbA1c measurement with High-performance liquid chromatography in diabetic patients.

Azadeh Karami, Azar Baradaran

Open access · goldAbstract read
In one paragraph

Article in Advanced biomedical research, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Effect of the different assays of HbA1c on diabetic patients monitoring.Journal of diabetes and metabolic disorders · 2015
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Azadeh KaramiDepartment of Pathology, Isfahan University of Medial Science, Iran.
Azar BaradaranDepartment of Pathology, Isfahan University of Medial Science, Iran.
University of Isfahan · IR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe global prevalence of diabetes mellitus is increasing rapidly. Measurement of glycated hemoglobin, predominantly HbA1c, is fundamental to the management of patients with diabetes. HbA1c is used to monitor long-term glycemic control, adjust therapy, assess the quality of diabetes care and predict the risk for the development of complications. While HbA1c is the standard method for long-term glycemic control in diabetic patients, there are different methods for measurement of HbA1c and all laboratories do not use the reference method (high-performance liquid chromatography [HPLC]). The objective of this study is comparison of three different methods with HPLC to find out which method has an acceptable concordance and correlation with the reference method. MATERIALS AND

methodsFifty-eight diabetic patients were assessed in this study. The blood sample of each patient was checked with Diazyme (enzymatic assay), Nycocard (boronate-affinity binding) and Biosystem (micro column chromatography). The values of HbA1c of each method were compared with the Knauer-HPLC results.

resultsTHE MEANS OF THE DIFFERENTIAL VALUES BETWEEN EACH METHOD AND HPLC IN THE ANOVA TEST ARE AS FOLLOWS: M = 1.8, SD = 1.09 for Nycocard-HPLC; M = 1.5, SD = 1.08 for biosystem-HPLC; M = 1.3, SD = 1.2 for Diazyme-HPLC. Pearson's correlation coefficient between HPLC and Nycocard; 0.76, HPLC and Diazyme; 0.75 and between HPLC and Biosystem was 0.68. Linear regression parameters for each method with HPLC were also determined.

conclusionDiazyme had a better performance and showed a greater concordance with HPLC among others, although it was not an ideal alternative for HPLC.

Indexed as

Column chromatographydiabetes mellitusenzymatic assayHbA1cHigh-performance liquid chromatography

Identifiers

PMID24800183
PMCPMC4007341
OpenAlexW2054015536

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked