ArticleAnalytical biochemistry2014
Measurement of the temperature of the resting rotor in analytical ultracentrifugation.
Article in Analytical biochemistry, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Strong non-ideality effects at low protein concentrations: considerations for elongated proteins.European biophysics journal : EBJ · 2023Article
- Article
- Best Practices for Aggregate Quantitation of Antibody Therapeutics by Sedimentation Velocity Analytical Ultracentrifugation.Journal of pharmaceutical sciences · 2022Review
- Calibrating analytical ultracentrifuges.European biophysics journal : EBJ · 2021Article
- Quantitative Analysis of Protein Self-Association by Sedimentation Velocity.Current protocols in protein science · 2020Article
- Measuring macromolecular size distributions and interactions at high concentrations by sedimentation velocity.Nature communications · 2018Article
- Article
- Biochemical Roles for Conserved Residues in the Bacterial Fatty Acid-binding Protein Family.The Journal of biological chemistry · 2016Article
- 3D-Printing for Analytical Ultracentrifugation.PloS one · 2016Article
- A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation.PloS one · 2015Article
- Conformation of the von Willebrand factor/factor VIII complex in quasi-static flow.The Journal of biological chemistryArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Accurate measurements of rotor temperature are critical for the interpretation of hydrodynamic parameters in analytical ultracentrifugation. We have recently developed methods for a more accurate determination of the temperature of a spinning rotor using iButton temperature loggers. Here we report that the temperature measured with the iButton on the counterbalance of a resting rotor, following thermal equilibration under high vacuum, closely corresponded to the temperature of the spinning rotor with a precision better than 0.2°C. This strategy offers an inexpensive and straightforward approach to monitor the accuracy of the temperature calibration and determine corrective temperature offsets.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.