ArticleHernia : the journal of hernias and abdominal wall surgery2014
A comparison of Progrip(®) and Adhesix (®) self-adhering hernia meshes in an onlay model in the rat.
Article in Hernia : the journal of hernias and abdominal wall surgery, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 30 citations in OpenAlex.
- Bioinstructive polymer fibre mats to reduce bacterial pathogen colonisation.RSC applied polymers · 2026Article
- Self-gripping versus polypropylene mesh for incisional hernia repair in a rat model.Surgical endoscopy · 2025Article
- Mesh fixation in laparoscopic groin hernia repair: a comprehensive review of techniques and devices.Hernia : the journal of hernias and abdominal wall surgery · 2025Review
- Medial incisional ventral hernia repair with AdhesixHernia : the journal of hernias and abdominal wall surgery · 2023Article
- Self-adhesive hydrogel meshes reduce tissue incorporation and mechanical behavior versus microgrips self-fixation: a preclinical study.Hernia : the journal of hernias and abdominal wall surgery · 2022Article
- Polymer Hernia Repair Materials: Adapting to Patient Needs and Surgical Techniques.Materials (Basel, Switzerland) · 2021Review
- Liquid antiadhesive agents for intraperitoneal hernia repair procedures: ArtissSurgical endoscopy · 2017Article
- Abdominal Wall Reconstruction Using Retrorectus Self-adhering Mesh: A Novel Approach.Plastic and reconstructive surgery. Global open · 2016Article
- Self-Gripping Meshes for Lichtenstein Repair. Do We Need Additional Suture Fixation?World journal of surgery · 2016Article
- Comment to "A comparison of Progrip® and Adhesix® self-adhering hernia meshes in an onlay model in the rat" Gruber-Blum S, Riepl N, Brand J, Keibl C, Redl H, Fortelny RH, Petter-Puchner AH (doi:10.1007/s10029-014-1258-0).Hernia : the journal of hernias and abdominal wall surgery · 2015Article
- Usage of a self-adhesive mesh in TAPP hernia repair: A prospective study based on Herniamed Register.Journal of minimal access surgeryArticle
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
7 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAtraumatic fixation is a key element of modern hernia repair. Two different concepts of self-adhering meshes were directly compared in this study. Adhesix(®) (AH) is coated with polyethylene glycol (PEG) and polyvinylpyrrolidone (PVP), whereas Parietene Progrip(®) (PP) relies on the mechanical principle of micro grips made of polylactic acid (PLA). These meshes are the main competitors in the field.
methodsAH and PP were tested in Sprague-Dawley rats at 14 and 90 days. Four groups were operated (n = 8 animals per group). Two meshes were implanted per animal in an operation model of onlay hernia repair. Dislocation, tissue integration and foreign-body reaction were evaluated.
resultsAH dislocated significantly more frequently (every second mesh) at both time points of observation than PP. Tissue integration was good with PP and could not be reliably assessed in AH due to frequent dislocation. Histologic examination revealed only a mild foreign body reaction in all groups.
conclusionsIn our hands, PP (mechanical grip fixation) was superior to hydrogel fixation with PEG and PVP in AH in an onlay model. The reason for dislocation of AH requires further clarification as well as the impact of long-term degradation of the PLA grips.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials