ArticleJournal of clinical laboratory analysis2015
Clinical application evaluation of two fourth-generation human immunodeficiency virus (HIV) screening assays in West China Hospital.
Article in Journal of clinical laboratory analysis, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- HIV testing algorithm using fourth generation reagents reduces the false positive rate of screening tests.Scientific reports · 2025Article
- A method to alleviate false-positive results of the Elecsys HIV combi PT assay.Scientific reports · 2021Article
- The evaluation of low cut-off index values of ElecsysJournal of clinical laboratory analysis · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundFourth-generation human immunodeficiency virus (HIV) screening assays have been used in many laboratories. The Elecsys® HIV combi PT assay is a new kind of fourth-generation HIV screening assay developed to allow earlier detection of seroconversion.
methodsA total of 271,845 routine specimens were detected using the Elecsys® HIV combi assay and Elecsys® HIV combi PT assay from September 2010 to December 2012 in a large university hospital. Repeatedly, reactive screening samples were confirmed according to recommended confirmatory algorithms.
resultsThe false-positive rate and positive predictive value (PPV) of two assays are 0.08 and 78.35%, respectively, for the Elecsys® HIV combi assay and 0.07 and 82.21% for the Elecsys® HIV combi PT assay. Ninety-four percent cases with cutoff index ratio <15.0 were false-positive. When we set the specificity as 95.0 and 99.0%, PPV could increase to 98.7, 99.6, 98.8, and 99.7%, and sensitivity reduced to 99.2, 98.4, 98.5, and 96.8% for the Elecsys® HIV combi assay and the Elecsys® HIV combi PT assay, respectively.
conclusionsThe Elecsys® HIV combi PT assay shows a better performance in specificity than the Elecsys® HIV combi assay. Most weakly reactive results were false-positive, this means it still need to be improved and it will need laboratory personnel to communicate with the clinical doctor and patients more properly about the result of the assay.