Evidence map›Paper›PMID 24794413›Full record

ArticleAnalytical chemistry2014

Monitoring charge flux to quantify unusual ligand-induced ion channel activity for use in biological nanopore-based sensors.

Florika C Macazo, Ryan J White

Abstract read
In one paragraph

Article in Analytical chemistry, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.2field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 28 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Review
  10. Article
  11. Reagentless, Structure-Switching, Electrochemical Aptamer-Based Sensors.Annual review of analytical chemistry (Palo Alto, Calif.) · 2016
    Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Florika C MacazoDepartment of Chemistry and Biochemistry, University of Maryland Baltimore County , 1000 Hilltop Circle, Baltimore, Maryland 21250, United States.
Ryan J White
University of Maryland, Baltimore County · US

Funding

EXPAND PARTICIPATION BY MINORITIES IN BIOMEDICAL SCIENCER25GM055036 · NIGMS · UNIVERSITY OF MARYLAND BALTIMORE COUNTY · PI SUMMERS, MICHAEL FINLEY · 1996 to 2021
$16.9M
Graduate Training at The Chemistry Biology InterfaceT32GM066706 · NIGMS · UNIVERSITY OF MARYLAND BALTIMORE COUNTY · PI SELEY-RADTKE, KATHERINE L, SMITH, AARON T · 2004 to 2023
$3.3M
NIGMS NIH HHS R25 GM055036NIGMS NIH HHS T32 GM066706NIGMS NIH HHS T32GM066706
6 · The paper itself

Abstract

The utility of biological nanopores for the development of sensors has become a growing area of interest in analytical chemistry. Their emerging use in chemical analysis is a result of several ideal characteristics. First, they provide reproducible control over nanoscale pore sizes with an atomic level of precision. Second, they are amenable to resistive-pulse type measurement systems when embedded into an artificial lipid bilayer. A single binding event causes a change in the flow of millions of ions across the membrane per second that is readily measured as a change in current with excellent signal-to-noise ratio. To date, ion channel-based biosensors have been limited to well-behaved proteins. Most demonstrations of using ion channels as sensors have been limited to proteins that remain in the open, conducting state, unless occupied by an analyte of interest. Furthermore, these proteins are nonspecific, requiring chemical, biochemical, or genetic manipulations to impart chemical specificity. Here, we report on the use of the pore-forming abilities of heat shock cognate 70 (Hsc70) to quantify a specific analyte. Hsc70 reconstitutes into phospholipid membranes and opens to form multiple conductance states specifically in the presence of ATP. We introduce the measurement of "charge flux" to characterize the ATP-regulated multiconductance nature of Hsc70, which enables sensitive quantification of ATP (100 μM-4 mM). We believe that monitoring protein-induced charge flux across a bilayer membrane represents a universal method for quantitatively monitoring ion-channel activity. This measurement has the potential to broaden the library of usable proteins in the development of nanopore-based biosensors.

Indexed as

Adenosine TriphosphateBiosensing TechniquesHSC70 Heat-Shock ProteinsIon ChannelsLigandsLipid BilayersMembranes, ArtificialNanoporesPhospholipidsAdenosine TriphosphateHSC70 Heat-Shock ProteinsIon ChannelsLigandsLipid BilayersMembranes, ArtificialPhospholipids

Identifiers

PMID24794413
PMCPMC4051251
OpenAlexW2013694761

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.