Evidence map›Paper›PMID 24791783›Full record

ArticleAmerican journal of physiology. Heart and circulatory physiology2014

The role of dye affinity in optical measurements of Cai(2+) transients in cardiac muscle.

Wei Kong, Vladimir G Fast

Open access · greenAbstract read
In one paragraph

Article in American journal of physiology. Heart and circulatory physiology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
1.9field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 15 citations in OpenAlex.

  1. Loss of Elmsan1 in cardiomyocytes leads to age-dependent cardiac dysfunction and reduced lifespan.American journal of physiology. Heart and circulatory physiology · 2025
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. A technical review of optical mapping of intracellular calcium within myocardial tissue.American journal of physiology. Heart and circulatory physiology · 2016
    Review
  9. Article
  10. Review
  11. Cardiac tissue slices: preparation, handling, and successful optical mapping.American journal of physiology. Heart and circulatory physiology · 2015
    Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Wei KongDepartment of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, Alabama.
Vladimir G FastDepartment of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, Alabama vfast@uab.edu.
University of Alabama at Birmingham · US

Funding

Mechanisms of Long Duration Fibrillation, Defibrillation and RefibrillationR01HL085370 · NHLBI · UNIVERSITY OF ALABAMA AT BIRMINGHAM · PI IDEKER, RAYMOND E. · 2007 to 2014
$2.9M
Mechanisms of Defibrillation &Shock-Induced ArrhythmiasR01HL067748 · NHLBI · UNIVERSITY OF ALABAMA AT BIRMINGHAM · PI FAST, VLADIMIR G · 2001 to 2012
$2.1M
NHLBI NIH HHS HL-067748NHLBI NIH HHS HL-85370
6 · The paper itself

Abstract

Previous experiments in cultures of neonatal rat myocytes demonstrated that the shape of Cai(2+) transients measured using high-affinity Ca(2+)-sensitive dyes may be misrepresented. The purpose of this study was to examine the role of dye affinity in Cai(2+) measurements in intact adult cardiac tissue by comparing optical recordings obtained with high- and low-affinity dyes. Experiments were carried out in porcine left ventricular (LV) wedge preparations stained locally by intramural injection via microcapillaries (diameter = 150 μm) with a low-affinity Ca(2+)-sensitive dye Fluo-4FF or Fluo-2LA (nominal Kd, ~7-10 μmol/l), high-affinity dye Rhod-2 (Kd = 0.57 μmol/l), and Fluo-4 or Fluo-2MA (Kd, ~0.4 μmol/l); in addition, tissue was stained with transmembrane potential (Vm)-sensitive dye RH-237. Optical recordings of Vm and Cai(2+) were made using optical fibers (diameter = 325 μm) glued with the microcapillaries. The durations of Cai(2+) transients measured at 50% level of recovery (CaD50) using high-affinity Fluo-4/Fluo-2MA dyes were up to ~81% longer than those measured with low-affinity Fluo-4FF/Fluo-2LA at long pacing cycle lengths (CL). In Fluo-4/Fluo-2MA measurements at long CLs, Cai(2+) transients often (~50% of cases) exhibited slow upstroke rise and extended plateau. In Rhod-2 measurements, CaD50 was moderately longer (up to ~35%) than in Fluo-4FF recordings, but Cai(2+) transient shapes were similar. In all series of measurements, mean action potential duration values were not significantly different (P > 0.05). The delays between Vm and Cai(2+) upstrokes were comparable for low- and high-affinity dyes (P > 0.05). In conclusion, measurements of Cai(2+) transient in ventricular myocardium are strongly affected by the affinity of Ca(2+) dyes. The high-affinity dyes may overestimate the duration and alter the shape of Cai(2+) transients.

Indexed as

AnimalsBinding SitesCalciumCalcium SignalingFluorescent DyesHeart VentriclesIn Vitro TechniquesMembrane PotentialsPyridinium CompoundsReproducibility of ResultsSensitivity and SpecificitySwineVoltage-Sensitive Dye Imaging4-(6-(4-dibutylaminophenyl)-1,3,5-hexatrienyl)-1-(4'-sulfobutyl)pyridiniumCalciumFluorescent DyesPyridinium Compoundsdye affinityintracellular calcium transientoptical fiberoptical mapping

Identifiers

PMID24791783
PMCPMC4080171
OpenAlexW2057529362

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.