Evidence map›Paper›PMID 24790909›Full record

ArticleAnnals of laboratory medicine2014

Evaluation of an immunochromatographic assay for the rapid and simultaneous detection of rotavirus and adenovirus in stool samples.

Jayoung Kim, Hyun Soo Kim, Han-Sung Kim, Jae-Seok Kim, Wonkeun Song, Kyu Man Lee, Sunhwa Lee, Kyoung Un Park, Woochang Lee, Young Jun Hong

Abstract readEvaluation Study
In one paragraph

Article in Annals of laboratory medicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Observational
  13. Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jayoung KimDepartment of Laboratory Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Hyun Soo KimDepartment of Laboratory Medicine, Hallym University College of Medicine, Hwaseong, Korea.
Han-Sung KimDepartment of Laboratory Medicine, Hallym University College of Medicine, Hwaseong, Korea.
Jae-Seok KimDepartment of Laboratory Medicine, Hallym University College of Medicine, Hwaseong, Korea.
Wonkeun SongDepartment of Laboratory Medicine, Hallym University College of Medicine, Hwaseong, Korea.
Kyu Man LeeDepartment of Laboratory Medicine, Hallym University College of Medicine, Hwaseong, Korea.
Sunhwa LeeSeegene Medical Foundation, Seoul, Korea.
Kyoung Un ParkDepartment of Laboratory Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.
Woochang LeeDepartment of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Young Jun HongDepartment of Laboratory Medicine, Korea Cancer Center Hospital, Seoul, Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWe evaluated the analytical and clinical performances of the SD BIOLINE Rota/Adeno Rapid kit (SD Rota/Adeno Rapid; Standard Diagnostics, Inc., Korea), an immunochromatographic assay (ICA), for the simultaneous detection of rotaviruses and adenoviruses in human stool samples.

methodsWe tested 400 clinical stool samples from patients with acute gastroenteritis and compared the ICA results with the results obtained by using ELISA, enzyme-linked fluorescent assays (ELFA), PCR, and multiplex reverse transcription-PCR (mRT-PCR). To assess the analytical performance of the SD BIOLINE Rota/Adeno Rapid kit, we determined its detection limit, reproducibility, cross-reactivity, and analytical reactivity for adenovirus subtypes, and performed interference studies.

resultsThe overall agreement rates among the tested methods were 91.5% for rotavirus and 85.5% for adenovirus. On the basis of mRT-PCR, the overall agreement, positive agreement, and negative agreement rates of the ICA were 95.6%, 100%, and 94.9% for rotavirus, and 94.0%, 71.4%, and 94.8% for adenovirus, respectively. Using the ICA, we detected all the subtypes of adenovirus tested, but the analytical reactivities for adenovirus subtypes were different between the 4 adenovirus detection methods. The high reproducibility was confirmed, and no cross-reactivity or interference was detected.

conclusionsThe SD BIOLINE Rota/Adeno Rapid kit showed acceptable analytical and clinical performances. However, interpretation of adenovirus positive/negative result should be cautious because of different detectability for adenovirus subtypes among adenovirus detection methods.

Indexed as

Chromatography, AffinityAcute DiseaseAdenoviridaeCross ReactionsDNA, ViralEnzyme-Linked Immunosorbent AssayFecesGastroenteritisHumansMultiplex Polymerase Chain ReactionReagent Kits, DiagnosticReproducibility of ResultsReverse Transcriptase Polymerase Chain ReactionRNA, ViralRotavirusDNA, ViralReagent Kits, DiagnosticRNA, ViralELISAImmunochromatographic assayPCRRotavirus

Identifiers

PMID24790909
PMCPMC3999320

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.