Evidence map›Paper›PMID 24771992›Full record

ArticleIEEE journal of selected topics in quantum electronics : a publication of the IEEE Lasers and Electro-optics Society2014

Integrated IVUS-OCT Imaging for Atherosclerotic Plaque Characterization.

Xiang Li, Jiawen Li, Joe Jing, Teng Ma, Shanshan Liang, Jun Zhang, Dilbahar Mohar, Aidan Raney, Sari Mahon, Matthew Brenner and 4 more

Abstract read
In one paragraph

Article in IEEE journal of selected topics in quantum electronics : a publication of the IEEE Lasers and Electro-optics Society, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 37 papers.

0numbers the graph read from it
0cells of the map it votes in
37citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

37 citing papers in PubMed.

  1. Article
  2. Single-Cell RNA Sequencing Reveals Granzyme KJournal of the American Heart Association · 2025
    Article
  3. Review
  4. Review
  5. Review
  6. Review
  7. Article
  8. Article
  9. Article
  10. Review
  11. Review
  12. Review
  13. Review
  14. Review
  15. Review
  16. Article
  17. Article
  18. Article
  19. Analysis and Design of High-Frequency 1-D CMUT Imaging Arrays in Noncollapsed Mode.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2019
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Xiang LiNIH Ultrasonic Transducer Resource Center and the Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA.
Jiawen LiDepartment of Biomedical Engineering, the Edwards Life Sciences Center for Advanced Cardiovascular Technology, and Beckman Laser Institute, University of California, Irvine, CA 92697 USA.
Joe JingDepartment of Biomedical Engineering and Beckman Laser Institute, University of California, Irvine, CA 92697 USA.
Teng MaNIH Ultrasonic Transducer Resource Center and the Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA.
Shanshan LiangDepartment of Biomedical Engineering and Beckman Laser Institute, University of California, Irvine, CA 92697 USA.
Jun ZhangDepartment of Biomedical Engineering and Beckman Laser Institute, University of California, Irvine, CA 92697 USA.
Dilbahar MoharDivision of Cardiology, Irvine Medical Center, University of California, Orange, CA 92868 USA.
Aidan RaneyDivision of Cardiology, Irvine Medical Center, University of California, Orange, CA 92868 USA.
Sari MahonBeckman Laser Institute, University of California, Irvine, CA 92697 USA.
Matthew BrennerDivision of Pulmonary and Critical Care, Irvine Medical Center, University of California, Orange, CA 92868 USA.
Pranav PatelEdwards Life Sciences Center for Advanced Cardiovascular Technology, University of California, Irvine, CA 92697 USA.
K Kirk ShungNIH Ultrasonic Transducer Resource Center and the Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA.
Qifa ZhouNIH Ultrasonic Transducer Resource Center and the Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA.
Zhongping ChenDepartment of Biomedical Engineering, the Edwards Life Sciences Center for Advanced Cardiovascular Technology, and Beckman Laser Institute, University of California, Irvine, CA 92697 USA.

Funding

A Resource on Medical Ultrasonic Transducer TechnologyP41EB002182 · NIBIB · UNIVERSITY OF SOUTHERN CALIFORNIA · PI SHUNG, K KIRK · 2003 to 2016
$13.3M
Virtual Photonocs TechnologiesP41EB015890 · NIBIB · UNIVERSITY OF CALIFORNIA-IRVINE · PI VENUGOPALAN, VASAN · 2012 to 2017
$7.0M
Modeling the Pediatric Upper Airway using A-OCT and Computational Fluid DynamicsR01HL105215 · NHLBI · UNIVERSITY OF CALIFORNIA-IRVINE · PI CHEN, ZHONGPING, ELGHOBASHI, SAID E. · 2010 to 2013
$3.7M
Diagnosis of Subglottic Stenosis and Edema in Neonates Using OCTR01HL103764 · NHLBI · UNIVERSITY OF CALIFORNIA-IRVINE · PI WONG, BRIAN · 2010 to 2014
$3.1M
Integrated multi-modality intravascular US/OCT imaging systemR01EB010090 · NIBIB · UNIVERSITY OF CALIFORNIA-IRVINE · PI CHEN, ZHONGPING · 2009 to 2012
$2.3M
High Resolution Optical Coherence Tomography for Early Airway Cancer DetectionR01CA124967 · NCI · UNIVERSITY OF CALIFORNIA-IRVINE · PI BRENNER, MATTHEW · 2007 to 2011
$1.3M
Evaluation of obstructive sleep apnea with long range 3D endoscopic FDOCTK25HL102055 · NHLBI · UNIVERSITY OF CALIFORNIA-IRVINE · PI ZHANG, JUN · 2011 to 2014
$495k
NCI NIH HHS R01 CA124967NHLBI NIH HHS K25 HL102055NHLBI NIH HHS R01 HL103764NHLBI NIH HHS R01 HL105215NIBIB NIH HHS P41 EB002182NIBIB NIH HHS P41 EB015890NIBIB NIH HHS R01 EB010090
6 · The paper itself

Abstract

For the diagnosis of atherosclerosis, biomedical imaging techniques such as intravascular ultrasound (IVUS) and optical coherence tomography (OCT) have been developed. The combined use of IVUS and OCT is hypothesized to remarkably increase diagnostic accuracy of vulnerable plaques. We have developed an integrated IVUS-OCT imaging apparatus, which includes the integrated catheter, motor drive unit, and imaging system. The dual-function imaging catheter has the same diameter of current clinical standard. The imaging system is capable for simultaneous IVUS and OCT imaging in real time.

Indexed as

intravascularIVUSmultimodalOCT

Identifiers

PMID24771992
PMCPMC3996710

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.