ArticleJournal of biomechanical engineering2014
Using a statistically calibrated biphasic finite element model of the human knee joint to identify robust designs for a meniscal substitute.
Article in Journal of biomechanical engineering, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it, 20 citations in OpenAlex.
- Large Animal Models of Meniscus Repair and Regeneration: A Systematic Review of the State of the Field.Tissue engineering. Part C, Methods · 2017Pooled it
- Reducing uncertainty when using knee-specific finite element models by assessing the effect of input parameters.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2017Article
- Evaluating the effects of material properties of artificial meniscal implant in the human knee joint using finite element analysis.Scientific reports · 2017Article
- Shape of chondrocytes within articular cartilage affects the solid but not the fluid microenvironment under unconfined compression.Acta biomaterialia · 2016Article
- A statistically-augmented computational platform for evaluating meniscal function.Journal of biomechanics · 2015Article
- A biphasic multiscale study of the mechanical microenvironment of chondrocytes within articular cartilage under unconfined compression.Journal of biomechanics · 2014Article
- A finite element implementation for biphasic contact of hydrated porous media under finite deformation and sliding.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
Abstract
This paper describes a methodology for selecting a set of biomechanical engineering design variables to optimize the performance of an engineered meniscal substitute when implanted in a population of subjects whose characteristics can be specified stochastically. For the meniscal design problem where engineering variables include aspects of meniscal geometry and meniscal material properties, this method shows that meniscal designs having simultaneously large radial modulus and large circumferential modulus provide both low mean peak contact stress and small variability in peak contact stress when used in the specified subject population. The method also shows that the mean peak contact stress is relatively insensitive to meniscal permeability, so the permeability used in the manufacture of a meniscal substitute can be selected on the basis of manufacturing ease or cost. This is a multiple objective problem with the mean peak contact stress over the population of subjects and its variability both desired to be small. The problem is solved by using a predictor of the mean peak contact stress across the tibial plateau that was developed from experimentally measured peak contact stresses from two modalities. The first experimental modality provided computed peak contact stresses using a finite element computational simulator of the dynamic tibial contact stress during axial dynamic loading. A small number of meniscal designs with specified subject environmental inputs were selected to make computational runs and to provide training data for the predictor developed below. The second experimental modality consisted of measured peak contact stress from a set of cadaver knees. The cadaver measurements were used to bias-correct and calibrate the simulator output. Because the finite element simulator is expensive to evaluate, a rapidly computable (calibrated) Kriging predictor was used to explore extensively the contact stresses for a wide range of meniscal engineering inputs and subject variables. The predicted values were used to determine the Pareto optimal set of engineering inputs to minimize peak contact stresses in the targeted population of subjects.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.