Evidence map›Paper›PMID 24767549›Full record

ArticleBMC pulmonary medicine2014

Exhaled breath profiling for diagnosing acute respiratory distress syndrome.

Lieuwe D J Bos, Marcus J Schultz, Peter J Sterk

Open access · goldAbstract read
In one paragraph

Article in BMC pulmonary medicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed, 1 pooled it
2.7field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 1 synthesis or guideline pooled it, 58 citations in OpenAlex.

  1. Pooled it
  2. Observational
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Review
  11. Article
  12. Review
  13. Review
  14. [Modern breath analysis].Medizinische Klinik, Intensivmedizin und Notfallmedizin · 2019
    Review
  15. Article
  16. Review
  17. Article
  18. Review
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Lieuwe D J BosDepartment of Intensive Care Medicine, Academic Medical Center, University of Amsterdam, Meibergdreef 9, G3-228, 1105 AZ Amsterdam, The Netherlands. l.d.bos@amc.uva.nl.
Marcus J Schultz
Peter J Sterk
Academic Medical Center · NLUniversity of Amsterdam · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe acute respiratory distress syndrome (ARDS) is a common, devastating complication of critical illness that is characterized by pulmonary injury and inflammation. The clinical diagnosis may be improved by means of objective biological markers. Electronic nose (eNose) technology can rapidly and non-invasively provide breath prints, which are profiles of volatile metabolites in the exhaled breath. We hypothesized that breath prints could facilitate accurate diagnosis of ARDS in intubated and ventilated intensive care unit (ICU) patients.

methodsProspective single-center cohort study with training and temporal external validation cohort. Breath of newly intubated and mechanically ventilated ICU-patients was analyzed using an electronic nose within 24 hours after admission. ARDS was diagnosed and classified by the Berlin clinical consensus definition. The eNose was trained to recognize ARDS in a training cohort and the diagnostic performance was evaluated in a temporal external validation cohort.

resultsIn the training cohort (40 patients with ARDS versus 66 controls) the diagnostic model for ARDS showed a moderate discrimination, with an area under the receiver-operator characteristic curve (AUC-ROC) of 0.72 (95%-confidence interval (CI): 0.63-0.82). In the external validation cohort (18 patients with ARDS versus 26 controls) the AUC-ROC was 0.71 [95%-CI: 0.54 - 0.87]. Restricting discrimination to patients with moderate or severe ARDS versus controls resulted in an AUC-ROC of 0.80 [95%-CI: 0.70 - 0.90]. The exhaled breath profile from patients with cardiopulmonary edema and pneumonia was different from that of patients with moderate/severe ARDS.

conclusionsAn electronic nose can rapidly and non-invasively discriminate between patients with and without ARDS with modest accuracy. Diagnostic accuracy increased when only moderate and severe ARDS patients were considered. This implicates that breath analysis may allow for rapid, bedside detection of ARDS, especially if our findings are reproduced using continuous exhaled breath profiling.

trial registrationNTR2750, registered 11 February 2011.

Indexed as

AgedBreath TestsFemaleHumansMaleMiddle AgedProspective StudiesRespiratory Distress SyndromeVolatile Organic CompoundsVolatile Organic Compounds

Identifiers

PMID24767549
PMCPMC4021554
OpenAlexW2046021885

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.