ArticleClinical orthopaedics and related research2014
Is tip apex distance as important as we think? A biomechanical study examining optimal lag screw placement.
Article in Clinical orthopaedics and related research, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 36 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
36 citing papers in PubMed, 1 synthesis or guideline pooled it, 79 citations in OpenAlex.
- No difference between lag screw and helical blade for cephalomedullary nail cut-out a systematic review and meta-analysis.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2022Pooled it
- Lag screw cutout risk factors in geriatric intertrochanteric femur fractures.BMC geriatrics · 2026Article
- The Effect of Lag Screw Position on Rotational Stability and Stress Concentration in Unstable Basicervical Intertrochanteric Fractures: A Finite Element Analysis.Journal of clinical medicine · 2026Article
- Measurement of the principal compressive trabeculae in the midcoronal plane of proximal femur and its significance in lag screw fixation.Journal of orthopaedic surgery and research · 2026Article
- The effect of compressive trabecular bone-cephalocervical implant relationship on stability in intertrochanteric femoral fractures: a clinical review and biomechanical research.Frontiers in bioengineering and biotechnology · 2025Article
- Biomechanical effects of FNS on femoral neck fractures based on different reduction quality: finite element analysis.BMC musculoskeletal disorders · 2024Article
- [Research progress on evaluation methods for head-neck nail position in femoral intertrochanteric fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2023Article
- A biomechanical analysis of the effect of hydroxyapatite augmentation for trochanteric femoral fractures.Experimental and therapeutic medicine · 2023Article
- Proposal of a modified tip apex distance for prediction of lag screw cut-out in trochanteric hip fractures.SICOT-J · 2023Article
- Mechanical effects of sagittal variations on Pauwels type III femoral neck fractures treated with Femoral Neck System(FNS).BMC musculoskeletal disorders · 2022Article
- The correlation between cutout and eccentric distance (ED) of the cephalic fixator tip in geriatric intertrochanteric fractures with internal fixation.Journal of orthopaedic surgery and research · 2022Article
- Risk factors for cut-outs in geriatric intertrochanteric fractures with cephalomedullary nailing after obtaining acceptable reduction: a case-control study.BMC musculoskeletal disorders · 2022Article
- An original method of simulating the articular cartilage in the context ofExperimental and therapeutic medicine · 2022Article
- Outcomes After Revision Fixation With Cement Augmentation for Failed Intertrochanteric Fracture Fixation in Older Adult Patients.Geriatric orthopaedic surgery & rehabilitation · 2022Article
- Eccentric distance zone analysis system: New regional evaluation of cephalic fixator tip location for predicting cut-out in geriatric intertrochanteric fractures with internal fixation.Frontiers in surgery · 2022Article
- CalTAD is the Key Evaluation Tool for Measurement of Cephalic Fixation Position for Predicting Cut-Out in Geriatric Intertrochanteric Fracture Patients with Internal Fixations after Achieving Acceptable Reduction.Geriatric orthopaedic surgery & rehabilitation · 2022Article
- [72/f-Stumbling fall onto the hips : Preparation for the medical specialist examination: part 42].Der Unfallchirurg · 2021Article
- Article
- Evaluation of the quadrants of femoral neck-head in the cephalomedullary fixation of intertrochanteric fractures with a helical blade: Is inferior posterior quadrant also safe? A clinical study.Joint diseases and related surgery · 2021Article
- [Comparison of the predictive value of tip-apex distance and calcar referenced tip-apex distance in treatment of femoral intertrochanteric fractures with Asian type proximal femoral nail fixation].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2020Article
Corrections and comments
- Erratum issued
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
Abstract
backgroundIntertrochanteric hip fractures pose a significant challenge for the orthopaedic community as optimal surgical treatment continues to be debated. Currently, varus collapse with lag screw cutout is the most common mode of failure. Multiple factors contribute to cutout. From a surgical technique perspective, a tip apex distance less than 25 mm has been suggested to decrease the risk of cutout. We hypothesized that a low-center lag screw position in the femoral head, with a tip apex distance greater than 25 mm will provide equal, if not superior, biomechanical stability compared with a center-center position with a tip apex distance less than 25 mm in an unstable intertrochanteric hip fracture stabilized with a long cephalomedullary nail. QUESTIONS/PURPOSES: We attempted to examine the biomechanical characteristics of intertrochanteric fractures instrumented with long cephalomedullary nails with two separate lag screw positions, center-center and low-center. Our first research purpose was to examine if there was a difference between the center-center and low-center groups in cycles to failure and failure load. Second, we analyzed if there was a difference in fracture translation between the study groups during loading.
methodsNine matched pairs of femurs were assigned to one of two treatment groups: low-center lag screw position and center-center lag screw position. Cephalomedullary nails were placed and tip apex distance was measured. A standard unstable four-part intertrochanteric fracture was created in all samples. The femurs were loaded dynamically until failure. Cycles to failure and load and displacement data were recorded, and three-dimensional (3-D) motion was recorded using an Optotrak(®) motion tracking system.
resultsThere were no significant differences between the low-center and center-center treatment groups regarding the mean number of cycles to failure and mean failure load. The 3-D kinematic data showed significantly increased motion in the center-center group compared with the low-center group. At the time of failure, the magnitude of fracture translation was statistically significantly greater in the center-center group (20 ± 2.8 mm) compared with the low-center group (15 ± 3.4 mm; p = 0.004). Additionally, there was statistically significantly increased fracture gap distraction (center-center group, 13 ± 2.8 versus low-center group, 7 ± 4; p < 0.001) and shear fracture gap translation (center-center group, 12 ± 2.3 mm; low-center group, 6 ± 2.7 mm; p < 0.001).
conclusionsPositioning of the lag screw inferior in the head and neck was found to be at least as biomechanically stable as the center-center group although the tip apex distance was greater than 25 mm. CLINICAL RELEVANCE: Our findings challenge previously accepted principles of optimal lag screw placement.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.