Evidence map›Paper›PMID 24752457›Full record

ArticleConference proceedings. IEEE International Conference on Systems, Man, and Cybernetics2013

Comparison of Baseline Tremor Under Various Microsurgical Conditions.

Trent S Wells, Sungwook Yang, Robert A Maclachlan, James T Handa, Peter Gehlbach, Cameron Riviere

Abstract read
In one paragraph

Article in Conference proceedings. IEEE International Conference on Systems, Man, and Cybernetics, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. A Data-Driven Model with Hysteresis Compensation for I... International Symposium on Medical Robotics. International Symposium on Medical Robotics · 2024
    Article
  2. Article
  3. Article
  4. Artificial intelligence and ophthalmic surgery.Current opinion in ophthalmology · 2021
    Review
  5. Article
  6. Hybrid position/force control of an active handheld micromanipulator for membrane peeling.The international journal of medical robotics + computer assisted surgery : MRCAS · 2016
    Article
  7. Robot assisted stapedotomy ex vivo with an active handheld instrument.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2015
    Article
  8. Toward Hybrid Position/Force Control for an Active Handheld Micromanipulator.IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation · 2014
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Trent S WellsDepartment of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA.
Sungwook YangThe Robotics Institute, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA.
Robert A MaclachlanThe Robotics Institute, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA.
James T HandaWilmer Eye Institute, Johns Hopkins University, Baltimore, Maryland, USA.
Peter GehlbachWilmer Eye Institute, Johns Hopkins University, Baltimore, Maryland, USA.
Cameron RiviereThe Robotics Institute, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA.

Funding

A Microsurgical Assistant SystemR01EB007969 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI TAYLOR, RUSSELL H · 2008 to 2012
$5.7M
An Active Handheld MicromanipulatorR01EB000526 · NIBIB · CARNEGIE-MELLON UNIVERSITY · PI RIVIERE, CAMERON N · 2003 to 2017
$2.6M
NIBIB NIH HHS R01 EB000526NIBIB NIH HHS R01 EB007969
6 · The paper itself

Abstract

This paper presents the characterization and comparison of physiological tremor for pointing tasks in multiple environments, as a baseline for performance evaluation of microsurgical robotics. Previous studies have examined the characteristics of physiological tremor under laboratory settings as well as different operating conditions. However, different test methods make the comparison of results across trials and conditions difficult. Two vitroretinal microsurgeons were evaluated while performing a pointing task with no entry-point constraint, constrained by an artificial eye model, and constrained by a rabbit eye in vivo. For the three respective conditions the 3D RMS positioning error was 144 μm, 258 μm, and 285 μm, and maximum 3D error was 349 μm, 647 μm, and 696 μm. A spectral analysis was also performed, confirming a distinct peak near in the 6-12 Hz frequency range, characteristic of hand tremor during tasks in all three environments.

Indexed as

accuracymedical roboticsmicrosurgeryphysiological tremorsmart instrumentstremor

Identifiers

PMID24752457
PMCPMC3989364

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.