ArticleThe international journal of cardiovascular imaging2014
Impact of strut-vessel distance and underlying plaque type on the resolution of acute strut malapposition: serial optimal coherence tomography analysis after everolimus-eluting stent implantation.
Article in The international journal of cardiovascular imaging, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Early vascular healing after neXt-generation drug-eluting stent implantation in Patients with non-ST elevation acute Coronary syndrome: a randomized optical coherence Tomography imaging study (EXPECT).The international journal of cardiovascular imaging · 2026Trial
- Insulin-like growth factor-1 levels predict myocardial injury and infarction after elective percutaneous coronary intervention: an optical coherence tomography study.Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2020Article
- Impact of lesion angle on optical coherence tomography findings and clinical outcomes after drug-eluting stent implantation in curved vessels.The international journal of cardiovascular imaging · 2019Article
- Cut-off value of mal-apposition volume and depth for resolution at early phase of acute incomplete stent apposition after CoCr-EES implantation.The international journal of cardiovascular imaging · 2019Observational
- Impact of lesion complexity on long-term vascular response to cobalt-chromium everolimus-eluting stent: five-year follow-up optical coherence tomography study.Heart and vessels · 2018Article
- Predictors and Long-Term Clinical Impact of Acute Stent Malapposition: An Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents (ADAPT-DES) Intravascular Ultrasound Substudy.Journal of the American Heart Association · 2016Article
- Optical coherence tomography analysis of the stent strut and prediction of resolved strut malapposition at 3 months after 2nd-generation drug-eluting stent implantation.Heart and vessels · 2016Article
- A Practical Approach to Assessing Stent Results with IVUS or OCT.Methodist DeBakey cardiovascular journalReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The consequences of acute strut malapposition in everolimus-eluting stents (EES) are unknown. This study investigated the impact of strut-vessel (S-V) distance and plaque type underneath acute strut malapposition on the mid-term vessel response in EES. Twenty-nine patients (35 EES) underwent optical coherence tomography (OCT) immediately after percutaneous coronary intervention and at 8-month follow-up. S-V distance and plaque type (lipid, calcified, or fibrous) underneath acute strut malapposition were evaluated. Follow-up OCT classified acute strut malapposition as persistent or resolved. The S-V cutoff value for predicting resolved strut malapposition and the incidence of intra-stent thrombi were determined. Among 569 cases of acute strut malapposition, involving 29,168 struts, 139 (24.4 %) were persistent. Mean S-V distance was significantly longer in persistent than in resolved strut malapposition (600 ± 294 vs. 231 ± 95 μm; P < 0.0001). S-V distance ≤380 μm was the best cutoff value for predicting resolved strut malapposition (sensitivity 93.5 %, specificity 69.8 %, area under curve 0.878). Acute strut malapposition with S-V distance ≤380 μm remained persistent more frequently over lipid/calcified than over fibrous plaques (lipid: 13.4 %, calcified: 18.2 %, fibrous: 4.2 %; lipid vs. fibrous, P = 0.001; calcified vs. fibrous, P = 0.02). Intra-stent thrombi were more frequent in stents with ≥1 persistent strut malapposition than in those without [4/11 stents (36.3 %) vs. 0/24 (0 %); P = 0.006]. Lipid and calcified plaque, together with S-V distance, affect the resolution of acute strut malapposition in EES. Persistent strut malapposition is associated with the presence of thrombi at follow-up, which could be the substrate for late stent thrombosis.
Indexed as
Identifiers
24748583What OpenQuestion holds
Registered trials