ArticleThe international journal of cardiovascular imaging2014

Impact of strut-vessel distance and underlying plaque type on the resolution of acute strut malapposition: serial optimal coherence tomography analysis after everolimus-eluting stent implantation.

Takumi Inoue, Toshiro Shinke, Hiromasa Otake, Masayuki Nakagawa, Hirotoshi Hariki, Tsuyoshi Osue, Masamichi Iwasaki, Yu Taniguchi, Ryo Nishio, Noritoshi Hiranuma and 4 more

Abstract read
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Observational
  5. Article
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Takumi InoueDivision of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017, Japan.
Toshiro Shinke
Hiromasa Otake
Masayuki Nakagawa
Hirotoshi Hariki
Tsuyoshi Osue
Masamichi Iwasaki
Yu Taniguchi
Ryo Nishio
Noritoshi Hiranuma
Akihide Konishi
Hiroto Kinutani
Masaru Kuroda
Ken-ichi Hirata

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The consequences of acute strut malapposition in everolimus-eluting stents (EES) are unknown. This study investigated the impact of strut-vessel (S-V) distance and plaque type underneath acute strut malapposition on the mid-term vessel response in EES. Twenty-nine patients (35 EES) underwent optical coherence tomography (OCT) immediately after percutaneous coronary intervention and at 8-month follow-up. S-V distance and plaque type (lipid, calcified, or fibrous) underneath acute strut malapposition were evaluated. Follow-up OCT classified acute strut malapposition as persistent or resolved. The S-V cutoff value for predicting resolved strut malapposition and the incidence of intra-stent thrombi were determined. Among 569 cases of acute strut malapposition, involving 29,168 struts, 139 (24.4 %) were persistent. Mean S-V distance was significantly longer in persistent than in resolved strut malapposition (600 ± 294 vs. 231 ± 95 μm; P < 0.0001). S-V distance ≤380 μm was the best cutoff value for predicting resolved strut malapposition (sensitivity 93.5 %, specificity 69.8 %, area under curve 0.878). Acute strut malapposition with S-V distance ≤380 μm remained persistent more frequently over lipid/calcified than over fibrous plaques (lipid: 13.4 %, calcified: 18.2 %, fibrous: 4.2 %; lipid vs. fibrous, P = 0.001; calcified vs. fibrous, P = 0.02). Intra-stent thrombi were more frequent in stents with ≥1 persistent strut malapposition than in those without [4/11 stents (36.3 %) vs. 0/24 (0 %); P = 0.006]. Lipid and calcified plaque, together with S-V distance, affect the resolution of acute strut malapposition in EES. Persistent strut malapposition is associated with the presence of thrombi at follow-up, which could be the substrate for late stent thrombosis.

Indexed as

Percutaneous Coronary InterventionTomography, Optical CoherenceAgedCoronary DiseaseDrug-Eluting StentsEverolimusFemaleHumansImmunosuppressive AgentsMalePlaque, AtheroscleroticPostoperative ComplicationsProsthesis FailureSensitivity and SpecificitySirolimusEverolimusImmunosuppressive AgentsSirolimus

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.