Evidence map›Paper›PMID 24737920›Full record

ArticleApplied physics letters2014

Confocal acoustic radiation force optical coherence elastography using a ring ultrasonic transducer.

Wenjuan Qi, Rui Li, Teng Ma, K Kirk Shung, Qifa Zhou, Zhongping Chen

Abstract read
In one paragraph

Article in Applied physics letters, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers.

0numbers the graph read from it
0cells of the map it votes in
27citing papers in PubMed
4.8field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

27 citing papers in PubMed, 46 citations in OpenAlex.

  1. Phantoms for use in optical coherence elastography.Journal of biomedical optics · 2026
    Review
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Wenjuan QiBeckman Laser Institute, University of California, Irvine, 1002 Health Sciences Road East, Irvine, California 92612, USA ; Department of Chemical Engineering and Materials Science, University of California, Irvine, Irvine, California 92697, USA.
Rui LiBeckman Laser Institute, University of California, Irvine, 1002 Health Sciences Road East, Irvine, California 92612, USA.
Teng MaDepartment of Biomedical Engineering, NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, California 90089, USA.
K Kirk ShungDepartment of Biomedical Engineering, NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, California 90089, USA.
Qifa ZhouDepartment of Biomedical Engineering, NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, California 90089, USA.
Zhongping ChenBeckman Laser Institute, University of California, Irvine, 1002 Health Sciences Road East, Irvine, California 92612, USA ; Department of Chemical Engineering and Materials Science, University of California, Irvine, Irvine, California 92697, USA ; Department of Biomedical Engineering, University of California, Irvine, Irvine, California 92697, USA.
University of Southern California · USBeckman Laser Institute and Medical Clinic · USUniversity of California, Irvine · US

Funding

Virtual Photonocs TechnologiesP41EB015890 · NIBIB · UNIVERSITY OF CALIFORNIA-IRVINE · PI DURKIN, ANTHONY · 2012 to 2017
$7.0M
Modeling the Pediatric Upper Airway using A-OCT and Computational Fluid DynamicsR01HL105215 · NHLBI · UNIVERSITY OF CALIFORNIA-IRVINE · PI CHEN, ZHONGPING, ELGHOBASHI, SAID E. · 2010 to 2013
$3.7M
Diagnosis of Subglottic Stenosis and Edema in Neonates Using OCTR01HL103764 · NHLBI · UNIVERSITY OF CALIFORNIA-IRVINE · PI WONG, BRIAN · 2010 to 2014
$3.1M
Integrated multi-modality intravascular US/OCT imaging systemR01EB010090 · NIBIB · UNIVERSITY OF CALIFORNIA-IRVINE · PI CHEN, ZHONGPING · 2009 to 2012
$2.3M
Elastographic Imaging of the Retina/Choroid in Age-Related Macular DegenerationR01EY021529 · NEI · COLUMBIA UNIVERSITY HEALTH SCIENCES · PI CHEN, ZHONGPING, SILVERMAN, RONALD H · 2012 to 2015
$1.4M
NEI NIH HHS R01 EY021529NHLBI NIH HHS R01 HL103764NHLBI NIH HHS R01 HL105215NIBIB NIH HHS P41 EB015890NIBIB NIH HHS R01 EB010090
6 · The paper itself

Abstract

We designed and developed a confocal acoustic radiation force optical coherence elastography system. A ring ultrasound transducer was used to achieve reflection mode excitation and generate an oscillating acoustic radiation force in order to generate displacements within the tissue, which were detected using the phase-resolved optical coherence elastography method. Both phantom and human tissue tests indicate that this system is able to sense the stiffness difference of samples and quantitatively map the elastic property of materials. Our confocal setup promises a great potential for point by point elastic imaging

Identifiers

PMID24737920
PMCPMC3971820
OpenAlexW2038023599

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.