Trial reportPloS one2014

Surgeons' exposure to radiation in single- and multi-level minimally invasive transforaminal lumbar interbody fusion; a prospective study.

Haruki Funao, Ken Ishii, Suketaka Momoshima, Akio Iwanami, Naobumi Hosogane, Kota Watanabe, Masaya Nakamura, Yoshiaki Toyama, Morio Matsumoto

Abstract readClinical Trial
In one paragraph

Trial report in PloS one, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed.

  1. Article
  2. Article
  3. Feasibility of synthetic CT images for robotic pedicle screw planning and navigation.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Association of occupational direct radiation exposure to the hands with longitudinal melanonychia and hand eczema in spine surgeons: a survey by the society for minimally invasive spinal treatment (MIST).European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2021
    Article
  12. Article
  13. Article
  14. Article
  15. A new protective method to reduce radiation exposure.Journal of spine surgery (Hong Kong) · 2020
    Article
  16. Article
  17. Article
  18. Observational
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Haruki FunaoDepartment of Orthopaedic Surgery, Nerima General Hospital, Tokyo, Japan; Society for Minimally invasive spine Stabilization (Clinical research group).
Ken IshiiDepartment of Orthopaedic Surgery, School of Medicine, Keio University, Tokyo, Japan; Society for Minimally invasive spine Stabilization (Clinical research group).
Suketaka MomoshimaDepartment of Radiology, School of Medicine, Keio University, Tokyo, Japan.
Akio IwanamiDepartment of Orthopaedic Surgery, School of Medicine, Keio University, Tokyo, Japan; Society for Minimally invasive spine Stabilization (Clinical research group).
Naobumi HosoganeDepartment of Orthopaedic Surgery, School of Medicine, Keio University, Tokyo, Japan; Society for Minimally invasive spine Stabilization (Clinical research group).
Kota WatanabeAdvanced Therapy for Spine and Spinal Cord Disorders, Keio University, Tokyo, Japan; Society for Minimally invasive spine Stabilization (Clinical research group).
Masaya NakamuraDepartment of Orthopaedic Surgery, School of Medicine, Keio University, Tokyo, Japan.
Yoshiaki ToyamaDepartment of Orthopaedic Surgery, School of Medicine, Keio University, Tokyo, Japan.
Morio MatsumotoDepartment of Orthopaedic Surgery, School of Medicine, Keio University, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Although minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) has widely been developed in patients with lumbar diseases, surgeons risk exposure to fluoroscopic radiation. However, to date, there is no studies quantifying the effective dose during MIS-TLIF procedure, and the radiation dose distribution is still unclear. In this study, the surgeons' radiation doses at 5 places on the bodies were measured and the effective doses were assessed during 31 consecutive 1- to 3-level MIS-TLIF surgeries. The operating surgeon, assisting surgeon, and radiological technologist wore thermoluminescent dosimeter on the unshielded thyroid, chest, genitals, right middle finger, and on the chest beneath a lead apron. The doses at the lens and the effective doses were also calculated. Mean fluoroscopy times were 38.7, 53.1, and 58.5 seconds for 1, 2, or 3 fusion levels, respectively. The operating surgeon's mean exposures at the lens, thyroid, chest, genitals, finger, and the chest beneath the shield, respectively, were 0.07, 0.07, 0.09, 0.14, 0.32, and 0.05 mSv in 1-level MIS-TLIF; 0.07, 0.08, 0.09, 0.18, 0.34, and 0.05 mSv in 2-level; 0.08, 0.09, 0.14, 0.15, 0.36, and 0.06 mSv in 3-level; and 0.07, 0.08, 0.10, 0.15, 0.33, and 0.05 mSv in all cases. Mean dose at the operating surgeon's right finger was significantly higher than other measurements parts (P<0.001). The operating surgeon's effective doses (0.06, 0.06, and 0.07 mSv for 1, 2, and 3 fusion levels) were low, and didn't differ significantly from those of the assisting surgeon or radiological technologist. Revision MIS-TLIF was not associated with higher surgeons' radiation doses compared to primary MIS-TLIF. There were significantly higher surgeons' radiation doses in over-weight than in normal-weight patients. The surgeons' radiation exposure during MIS-TLIF was within the safe level by the International Commission on Radiological Protection's guidelines. The accumulated radiation exposure, especially to surgeon's hands, should be carefully monitored.

Indexed as

Radiation DosageRadiation MonitoringAdultAgedFemaleHumansIntraoperative PeriodMaleMiddle AgedMinimally Invasive Surgical ProceduresOccupational ExposureProspective StudiesRadiation ProtectionSafetySpinal FusionSurgeons