Evidence map›Paper›PMID 24729218›Full record

ArticleAdvances in experimental medicine and biology2014

Real-time, in vivo determination of dynamic changes in lung and heart tissue oxygenation using EPR oximetry.

Brian K Rivera, Shan K Naidu, Kamal Subramanian, Matthew Joseph, Huagang Hou, Nadeem Khan, Harold M Swartz, Periannan Kuppusamy

Abstract read
In one paragraph

Article in Advances in experimental medicine and biology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.0field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 20 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Review
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Brian K RiveraDepartment of Internal Medicine, Davis Heart and Lung Research Institute, The Ohio State University Wexner Medical Center, Columbus, OH, 43210, USA.
Shan K NaiduDepartment of Internal Medicine, Davis Heart and Lung Research Institute, The Ohio State University Wexner Medical Center, Columbus, OH, 43210, USA.
Kamal SubramanianDepartment of Internal Medicine, Davis Heart and Lung Research Institute, The Ohio State University Wexner Medical Center, Columbus, OH, 43210, USA.
Matthew JosephDepartment of Internal Medicine, Davis Heart and Lung Research Institute, The Ohio State University Wexner Medical Center, Columbus, OH, 43210, USA.
Huagang HouEPR Center for the Study of Viable Systems, Department of Radiology, Geisel School of Medicine at Dartmouth, 48 Lafayette Street, Lebanon, NH, 03766, USA.
Nadeem KhanEPR Center for the Study of Viable Systems, Department of Radiology, Geisel School of Medicine at Dartmouth, 48 Lafayette Street, Lebanon, NH, 03766, USA.
Harold M SwartzEPR Center for the Study of Viable Systems, The Geisel School of Medicine at Dartmouth, Lebanon, NH, USA.
Periannan KuppusamyEPR Center for the Study of Viable Systems, Department of Radiology, Geisel School of Medicine at Dartmouth, 48 Lafayette Street, Lebanon, NH, 03766, USA. Periannan.Kuppusamy@Dartmouth.edu.
The Ohio State University Wexner Medical Center · USDartmouth College · US

Funding

Probes and Methods for Clinical OximetryR01EB004031 · NIBIB · OHIO STATE UNIVERSITY · PI KUPPUSAMY, PERIANNAN · 2004 to 2021
$7.1M
NIBIB NIH HHS R01 EB004031
6 · The paper itself

Abstract

The use of electron paramagnetic resonance (EPR) oximetry for oxygen measurements in deep tissues (>1 cm) is challenging due to the limited penetration depth of the microwave energy. To overcome this limitation, implantable resonators, having a small (0.5 mm diameter) sensory loop containing the oxygen-sensing paramagnetic material connected by a pair of twisted copper wire to a coupling loop (8-10 mm diameter), have been developed, which enable repeated measurements of deep-tissue oxygen levels (pO2, partial pressure of oxygen) in the brain and tumors of rodents. In this study, we have demonstrated the feasibility of measuring dynamic changes in pO2 in the heart and lung of rats using deep-tissue implantable oxygen sensors. The sensory loop of the resonator contained lithium octa-n-butoxynaphthalocyanine (LiNc-BuO) crystals embedded in polydimethylsiloxane (PDMS) polymer and was implanted in the myocardial tissue or lung pleura. The external coupling loop was secured subcutaneously above chest. The rats were exposed to different breathing gas mixtures while undergoing EPR measurements. The results demonstrated that implantable oxygen sensors provide reliable measurements of pO2 in deep tissues such as heart and lung under adverse conditions of cardiac and respiratory motions.

Indexed as

AnimalsDimethylpolysiloxanesElectron Spin Resonance SpectroscopyLungMyocardiumOximetryOxygenRatsRats, Sprague-DawleybaysilonDimethylpolysiloxanesOxygen

Identifiers

PMID24729218
PMCPMC4330333
OpenAlexW171884933

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.