ArticleAJNR. American journal of neuroradiology2014
Effect of structural remodeling (retraction and recoil) of the pipeline embolization device on aneurysm occlusion rate.
Article in AJNR. American journal of neuroradiology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Incidence and Outcomes of Flow Diverter Braid Deformation following Treatment with Non-DFT Wire Devices.Neurologia medico-chirurgica · 2026Article
- Silk + flow-diverter stent for the treatment of intracranial aneurysms associated with balloon angioplasty: A retrospective study.Surgical neurology international · 2023Article
- Two- to five-year follow-up of 78 patients after treatment with the Flow Redirection Endoluminal Device.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2020Article
- Mechanism of Action and Biology of Flow Diverters in the Treatment of Intracranial Aneurysms.Neurosurgery · 2020Review
- Is there an association between flow diverter fish mouthing and delayed-type hypersensitivity to metals?-a case-control study.Neuroradiology · 2017Article
- Emerging Technologies in Flow Diverters and Stents for Cerebrovascular Diseases.Current neurology and neuroscience reports · 2017Review
- Wall Apposition Is a Key Factor for Aneurysm Occlusion after Flow Diversion: A Histologic Evaluation in 41 Rabbits.AJNR. American journal of neuroradiology · 2016Article
- Metal coverage ratio of pipeline embolization device for treatment of unruptured aneurysms: Reality check.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeDuring endovascular treatment of unruptured aneurysms with the Pipeline Embolization Device, an oversized device is often selected to achieve better wall apposition; however, this device oversizing could be related to overelongation and possible delayed enlargement of the stented region. The purpose of this study is to investigate the relationship between oversize and treatment outcome. MATERIALS AND
methodsThe DynaCT images of 14 aneurysms treated by a single Pipeline Embolization Device were retrospectively analyzed. 3D images of the deployed device were compared with those acquired at the 6-month follow-up for qualitative and quantitative evaluation. The diameter and length of the Pipeline Embolization Device were measured at both time points and compared for determination of the device changes.
resultsStructural changes of the device have been observed, and it was found that the Pipeline Embolization Device influences the vessel curvature in some cases. On average, it increases its diameter by 0.23 mm and decreases its length by 2.88 mm within 6 months of initial deployment. Excessive elongation beyond its nominal length is correlated with a lower aneurysm occlusion rate at the 6-month follow-up.
conclusionsNot only does a Pipeline Embolization Device reconstruct the aneurysm and parent artery, but its entire structure goes through a gradual remodeling process. The relative deformation between the device and the artery indicates suboptimal wall apposition. Device oversizing does not have a direct effect on shortening or recoil. The aneurysm occlusion rate, however, is lowered by overelongation of the Pipeline Embolization Device.
Indexed as