Evidence map›Paper›PMID 24708745›Full record

ArticleBreast cancer research : BCR2014

A methodology to ensure and improve accuracy of Ki67 labelling index estimation by automated digital image analysis in breast cancer tissue.

Arvydas Laurinavicius, Benoit Plancoulaine, Aida Laurinaviciene, Paulette Herlin, Raimundas Meskauskas, Indra Baltrusaityte, Justinas Besusparis, Darius Dasevicius, Nicolas Elie, Yasir Iqbal and 1 more

Open access · goldAbstract read
In one paragraph

Article in Breast cancer research : BCR, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 53 papers.

0numbers the graph read from it
0cells of the map it votes in
53citing papers in PubMed
4.4field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

53 citing papers in PubMed, 100 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Clinical validity and clinical utility of Ki67 in early breast cancer.Therapeutic advances in medical oncology · 2022
    Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 3 countries.

Arvydas Laurinavicius
Benoit Plancoulaine
Aida Laurinaviciene
Paulette Herlin
Raimundas Meskauskas
Indra Baltrusaityte
Justinas Besusparis
Darius Dasevicius
Nicolas Elie
Yasir Iqbal
Catherine Bor
Vilnius University · LTUniversité de Caen Normandie · FRUniversity of Nottingham · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionImmunohistochemical Ki67 labelling index (Ki67 LI) reflects proliferative activity and is a potential prognostic/predictive marker of breast cancer. However, its clinical utility is hindered by the lack of standardized measurement methodologies. Besides tissue heterogeneity aspects, the key element of methodology remains accurate estimation of Ki67-stained/counterstained tumour cell profiles. We aimed to develop a methodology to ensure and improve accuracy of the digital image analysis (DIA) approach.

methodsTissue microarrays (one 1-mm spot per patient, n = 164) from invasive ductal breast carcinoma were stained for Ki67 and scanned. Criterion standard (Ki67-Count) was obtained by counting positive and negative tumour cell profiles using a stereology grid overlaid on a spot image. DIA was performed with Aperio Genie/Nuclear algorithms. A bias was estimated by ANOVA, correlation and regression analyses. Calibration steps of the DIA by adjusting the algorithm settings were performed: first, by subjective DIA quality assessment (DIA-1), and second, to compensate the bias established (DIA-2). Visual estimate (Ki67-VE) on the same images was performed by five pathologists independently.

resultsANOVA revealed significant underestimation bias (P < 0.05) for DIA-0, DIA-1 and two pathologists' VE, while DIA-2, VE-median and three other VEs were within the same range. Regression analyses revealed best accuracy for the DIA-2 (R-square = 0.90) exceeding that of VE-median, individual VEs and other DIA settings. Bidirectional bias for the DIA-2 with overestimation at low, and underestimation at high ends of the scale was detected. Measurement error correction by inverse regression was applied to improve DIA-2-based prediction of the Ki67-Count, in particularfor the clinically relevant interval of Ki67-Count < 40%. Potential clinical impact of the prediction was tested by dichotomising the cases at the cut-off values of 10, 15, and 20%. Misclassification rate of 5-7% was achieved, compared to that of 11-18% for the VE-median-based prediction.

conclusionsOur experiments provide methodology to achieve accurate Ki67-LI estimation by DIA, based on proper validation, calibration, and measurement error correction procedures, guided by quantified bias from reference values obtained by stereology grid count. This basic validation step is an important prerequisite for high-throughput automated DIA applications to investigate tissue heterogeneity and clinical utility aspects of Ki67 and other immunohistochemistry (IHC) biomarkers.

Indexed as

AlgorithmsAnalysis of VarianceBreast NeoplasmsCarcinoma, Ductal, BreastCell ProliferationFemaleHumansImage Processing, Computer-AssistedImmunohistochemistryKi-67 AntigenLinear ModelsMitotic IndexPrognosisReproducibility of ResultsSensitivity and SpecificityTissue Array AnalysisKi-67 Antigen

Identifiers

PMID24708745
PMCPMC4053156
OpenAlexW2164360023

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.