ArticleSensors (Basel, Switzerland)2014
Dielectrophoretic manipulation and separation of microparticles using microarray dot electrodes.
Article in Sensors (Basel, Switzerland), 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed.
- Surface-Sensitive Fractioning of Flowing Colloidal Suspensions Sedimented at a Photochemically Active Wall.Small (Weinheim an der Bergstrasse, Germany) · 2025Article
- Joint subarray acoustic tweezers enable controllable cell translation, rotation, and deformation.Nature communications · 2024Article
- Recent advances to address challenges in extracellular vesicle-based applications for lung cancer.Acta pharmaceutica Sinica. B · 2024Review
- Dielectrophoretic profiling of erythrocytes to study the impacts of metabolic stress, temperature, and storage duration utilizing a point-and-planar microdevice.Scientific reports · 2023Article
- Magnetophoretic circuits: A review of device designs and implementation for precise single-cell manipulation.Analytica chimica acta · 2023Review
- Artificial Intelligence Algorithms Enable Automated Characterization of the Positive and Negative Dielectrophoretic Ranges of Applied Frequency.Micromachines · 2022Article
- Integration of a Dielectrophoretic Tapered Aluminum Microelectrode Array with a Flow Focusing Technique.Sensors (Basel, Switzerland) · 2021Article
- Microfluidic Synthesis, Control, and Sensing of Magnetic Nanoparticles: A Review.Micromachines · 2021Review
- Article
- Characterization and Separation of Live and Dead Yeast Cells Using CMOS-Based DEP Microfluidics.Micromachines · 2021Article
- Dielectrophoretic Characterization of Tenogenically Differentiating Mesenchymal Stem Cells.Biosensors · 2021Article
- DEP-Dots for 3D cell culture: low-cost, high-repeatability, effective 3D cell culture in multiple gel systems.Scientific reports · 2020Article
- Dielectrophoretic Immobilization of Yeast Cells Using CMOS Integrated Microfluidics.Micromachines · 2020Article
- Nucleotide Identification in DNA Using Dielectrophoresis Spectroscopy.Micromachines · 2019Article
- Continuous-Flow Cell Dipping and Medium Exchange in a Microdevice using Dielectrophoresis.Micromachines · 2018Article
- Tailoring particle translocation via dielectrophoresis in pore channels.Scientific reports · 2016Article
- Cell patterning for liver tissue engineering via dielectrophoretic mechanisms.Sensors (Basel, Switzerland) · 2014Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This paper introduces a dielectrophoretic system for the manipulation and separation of microparticles. The system is composed of five layers and utilizes microarray dot electrodes. We validated our system by conducting size-dependent manipulation and separation experiments on 1, 5 and 15 μm polystyrene particles. Our findings confirm the capability of the proposed device to rapidly and efficiently manipulate and separate microparticles of various dimensions, utilizing positive and negative dielectrophoresis (DEP) effects. Larger size particles were repelled and concentrated in the center of the dot by negative DEP, while the smaller sizes were attracted and collected by the edge of the dot by positive DEP.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.