Evidence map›Paper›PMID 24699259›Full record

Trial reportPloS one2014

Examination of different accelerometer cut-points for assessing sedentary behaviors in children.

Youngwon Kim, Jung-Min Lee, Bradley P Peters, Glenn A Gaesser, Gregory J Welk

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in PloS one, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
27citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

27 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Observational
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Hip and Wrist-Worn Accelerometer Data Analysis for Toddler Activities.International journal of environmental research and public health · 2019
    Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Youngwon KimDepartment of Kinesiology, Iowa State University, Ames, Iowa, United States of America.
Jung-Min LeeSchool of Health, Physical Education and Recreation College of Education, University of Nebraska, Omaha, Nebraska, United States of America.
Bradley P PetersDepartment of Kinesiology, Iowa State University, Ames, Iowa, United States of America.
Glenn A GaesserSchool of Nutrition and Health Promotion, Arizona State University, Phoenix, Arizona, United States of America.
Gregory J WelkDepartment of Kinesiology, Iowa State University, Ames, Iowa, United States of America.

Funding

NHLBI NIH HHS R01 HL910006
6 · The paper itself

Abstract

backgroundPublic health research on sedentary behavior (SB) in youth has heavily relied on accelerometers. However, it has been limited by the lack of consensus on the most accurate accelerometer cut-points as well as by unknown effects caused by accelerometer position (wrist vs. hip) and output (single axis vs. multiple axes). The present study systematically evaluates classification accuracy of different Actigraph cut-points for classifying SB using hip and wrist-worn monitors and establishes new cut-points to enable use of the 3-dimensional vector magnitude data (for both hip and wrist placement).

methodsA total of 125 children ages 7-13 yrs performed 12 randomly selected activities (from a set of 24 different activities) for 5 min each while wearing tri-axial Actigraph accelerometers on both the hip and wrist. The accelerometer data were categorized as either sedentary or non-sedentary minutes using six previously studied cut-points: 100 counts-per-minute (CPM), 200 CPM, 300 CPM, 500 CPM, 800 CPM and 1100 CPM. Classification accuracy was evaluated with Cohen's Kappa (κ) and new cut-points were identified from Receiver Operating Characteristic (ROC).

resultsOf the six cut-points, the 100 CPM value yielded the highest classification accuracy (κ = 0.81) for hip placement. For wrist placement, all of the cut-points produced low classification accuracy (ranges of κ from 0.44 to 0.67). Optimal sedentary cut-points derived from ROC were 554.3 CPM (ROC-AUC of 0.99) for vector magnitude for hip, 1756 CPM (ROC-AUC of 0.94) for vertical axis for wrist, and 3958.3 CPM (ROC-AUC of 0.93) for vector magnitude for wrist placement.

conclusionsThe 100 CPM was supported for use with vertical axis for hip placement, but not for wrist placement. The ROC-derived cut-points can be used to classify youth SB with the wrist and with vector magnitude data.

Indexed as

Sedentary BehaviorAccelerometryAdolescentBody Mass IndexChildExerciseFemaleHipHumansMaleMonitoring, AmbulatoryMotor ActivitySportsWrist

Identifiers

PMID24699259
PMCPMC3974658

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.