Effective dose to patient measurements in flat-detector and multislice computed tomography: a comparison of applications in neuroradiology.

Tobias Struffert, Michael Hauer, Rosemarie Banckwitz, Christoph Köhler, Kevin Royalty, Arnd Doerfler

Abstract readComparative StudyEvaluation Study
PubMed Publisher
In one paragraph

Article in European radiology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 39 papers.

0numbers the graph read from it
0cells of the map it votes in
39citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

39 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Can flat-detector CT after successful endovascular treatment predict long-term outcome in patients with large vessel occlusion? An Alberta Stroke Programme Early CT Score-based study.Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2023
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Image quality of flat-panel computed tomography using 2 different acquisition times versus multidetector computed tomography in whole-head temporal bone specimen.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Tobias StruffertDepartment of Neuroradiology, University of Erlangen-Nuremberg, Schwabachanlage 6, 91054, Erlangen, Germany, tobias.struffert@uk-erlangen.de.
Michael Hauer
Rosemarie Banckwitz
Christoph Köhler
Kevin Royalty
Arnd Doerfler

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeFlat-detector CT (FD-CT) is used for a variety of applications. Additionally, 3D rotational angiography (3D DSA) is used to supplement digital subtraction angiography (DSA) studies. The aim was to measure and compare the dose of (1) standard DSA and 3D DSA and (2) analogous FD-CT and multislice CT (MSCT) protocols.

methodsUsing an anthropomorphic phantom, the effective dose to patients (according to ICRP 103) was measured on an MSCT and a flat-detector angiographic system using standard protocols as recommended by the manufacturer.

results(1) Evaluation of DSA and 3D DSA angiography protocols: ap.-lat. Standard/low-dose series 1/0.8 mSv, enlarged oblique projection 0.3 mSv, 3D DSA 0.9 mSv (limited coverage length 0.3 mSv). (2) Comparison of FD-CT and MSCT: brain parenchyma imaging 2.9 /1.4 mSv, perfusion imaging 2.3/4.2 mSv, temporal bone 0.2 /0.2 mSv, angiography 2.9/3.3 mSv, limited to the head using collimation 0.5/0.5 mSv.

conclusionThe effective dose for an FD-CT application depends on the application used. Using collimation for FD-CT applications, the dose may be reduced considerably. Due to the low dose of 3D DSA, we recommend using this technique to reduce the number of DSA series needed to identify working projections. KEY POINTS: Effective dose of FD-CT in comparison to MSCT is in comparable range. Collimation decreases the dose of FD-CT effectively. Effective dose of 3-D angiography is identical to 2-D DSA. Different FD-CT programs have different dose.