Evidence map›Paper›PMID 24688229›Full record

ArticleAnnals of pediatric cardiology2013

Amplatzer vascular plugs in congenital cardiovascular malformations.

Parag Barwad, Sivasubramanian Ramakrishnan, Shyam S Kothari, Anita Saxena, Saurabh K Gupta, Rajnish Juneja, Gurpreet Singh Gulati, Priya Jagia, Sanjiv Sharma

Open access · diamondAbstract read
In one paragraph

Article in Annals of pediatric cardiology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 19 citations in OpenAlex.

  1. Observational
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Platelet-rich plasma for open meniscal repair in young patients: any benefit?Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2015
    Article
  8. Review
  9. Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Parag BarwadDepartment of Cardiology, All India Institute of Medical Sciences, New Delhi, India.
Sivasubramanian RamakrishnanDepartment of Cardiology, All India Institute of Medical Sciences, New Delhi, India.
Shyam S KothariDepartment of Cardiology, All India Institute of Medical Sciences, New Delhi, India.
Anita SaxenaDepartment of Cardiology, All India Institute of Medical Sciences, New Delhi, India.
Saurabh K GuptaDepartment of Cardiology, All India Institute of Medical Sciences, New Delhi, India.
Rajnish JunejaDepartment of Cardiology, All India Institute of Medical Sciences, New Delhi, India.
Gurpreet Singh GulatiDepartment of Cardiac Radiology, All India Institute of Medical Sciences, New Delhi, India.
Priya JagiaDepartment of Cardiac Radiology, All India Institute of Medical Sciences, New Delhi, India.
Sanjiv SharmaDepartment of Cardiac Radiology, All India Institute of Medical Sciences, New Delhi, India.
All India Institute of Medical Sciences · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAmplatzer vascular plugs (AVPs) are devices ideally suited to close medium-to-large vascular communications. There is limited published literature regarding the utility of AVPs in congenital cardiovascular malformations (CCVMs).

aimsTo describe the use of AVPs in different CCVMs and to evaluate their safety and efficacy. MATERIALS AND

methodsAll patients who required an AVP for the closure of CCVM were included in this retrospective review of our catheterization laboratory data. The efficacy and safety of AVPs are reported.

resultsA total of 39 AVPs were implanted in 31 patients. Thirteen (33%) were AVP type I and 23 (59%) were AVP type II. AVP type III were implanted in two patients and type IV in one patient. The major indications for their use included closure of pulmonary arteriovenous malformation (AVM) (n = 7), aortopulmonary collaterals (n = 7), closure of a patent Blalock-Taussig shunt (n = 5), systemic AVM (n = 5), coronary AVM (n = 4), patent ductus arteriosus (PDA) (n = 3), pulmonary artery aneurysms (n = 3), and venovenous collaterals (n = 2). Deployment of the AVP was done predominantly via the 5 - 7F Judkin's right coronary guide catheter. Overall 92% of the AVPs could be successfully deployed and resulted in occlusion of the target vessel in all cases, within 10 minutes. No procedure-related or access site complication occurred.

conclusionsAVPs are versatile, easy to use, and effective devices to occlude the vascular communications in a variety of settings. AVP II is especially useful in the closure of tubular structures with a high flow.

Indexed as

Amplatzer vascular plugcongenital heart diseasedevice therapy

Identifiers

PMID24688229
PMCPMC3957441
OpenAlexW2092816568

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.