Evidence map›Paper›PMID 24686689›Full record

ArticleOptics letters2014

Fully motorized optical-resolution photoacoustic microscopy.

Lei Li, Chenghung Yeh, Song Hu, Lidai Wang, Brian T Soetikno, Ruimin Chen, Qifa Zhou, K Kirk Shung, Konstantin I Maslov, Lihong V Wang

Open access · bronzeAbstract read
In one paragraph

Article in Optics letters, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 36 papers.

0numbers the graph read from it
0cells of the map it votes in
36citing papers in PubMed
5.0field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

36 citing papers in PubMed, 79 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Super-Low-Dose Functional and Molecular Photoacoustic Microscopy.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023
    Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Multiscale Photoacoustic Tomography of a Genetically Encoded Near-Infrared FRET Biosensor.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2021
    Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Lei Li
Chenghung Yeh
Song Hu
Lidai Wang
Brian T Soetikno
Ruimin Chen
Qifa Zhou
K Kirk Shung
Konstantin I Maslov
Lihong V Wang
Optica · USUniversity of Southern California · USWashington University in St. Louis · US

Funding

A Resource on Medical Ultrasonic Transducer TechnologyP41EB002182 · NIBIB · UNIVERSITY OF SOUTHERN CALIFORNIA · PI SHUNG, K KIRK · 2003 to 2016
$13.3M
PHOTON TUNNELING: SHEDDING NEW LIGHT ON BIOMEDICINEDP1EB016986 · NIBIB · WASHINGTON UNIVERSITY · PI WANG, LIHONG · 2012 to 2016
$3.8M
PHOTOACOUSTIC MICROSCOPY OF NEOVASCULARIZATION IN RENAL CANCER GROWTH AND THERAPYR01CA159959 · NCI · WASHINGTON UNIVERSITY · PI ARBEIT, JEFFREY MICHAEL · 2011 to 2015
$2.9M
Monitoring of Breast Neoadjuvant Therapy by Thermo- and Photo- Acoustic TomographR01CA134539 · NCI · WASHINGTON UNIVERSITY · PI MONSEES, BARBARA, WANG, LIHONG · 2009 to 2013
$2.9M
NCCDPHP CDC HHS DP1 EB016986NCI NIH HHS R01 CA134539NCI NIH HHS R01 CA159959NIBIB NIH HHS DP1 EB016986NIBIB NIH HHS P41 EB002182
6 · The paper itself

Abstract

We have developed fully motorized optical-resolution photoacoustic microscopy (OR-PAM), which integrates five complementary scanning modes and simultaneously provides a high imaging speed and a wide field of view (FOV) with 2.6 μm lateral resolution. With one-dimensional (1D) motion-mode mechanical scanning, we measured the blood flow through a cross section of a blood vessel in vivo. With two-dimensional (2D) optical scanning at a laser repetition rate of 40 kHz, we achieved a 2 kHz B-scan rate over a range of 50 μm with 20 A-lines and 50 Hz volumetric-scan rate over a FOV of 50  μm × 50  μm with 400 A-lines, which enabled real-time tracking of cellular dynamics in vivo. With synchronized 1D optical and 2D mechanical hybrid scanning, we imaged a 10  mm × 8  mm FOV within three minutes, which is 20 times faster than the conventional mechanical scan in our second-generation OR-PAM. With three-dimensional mechanical contour scanning, we maintained the optimal signal-to-noise ratio and spatial resolution of OR-PAM while imaging objects with uneven surfaces, which is essential for quantitative studies.

Indexed as

Optical PhenomenaAnimalsEarEquipment DesignErythrocytesHemoglobinsMiceMicroscopyPhotoacoustic TechniquesHemoglobins