Evidence map›Paper›PMID 24676894›Full record

ArticleJournal of the American Society for Mass Spectrometry2014

Improving the sensitivity of mass spectrometry by using a new sheath flow electrospray emitter array at subambient pressures.

Jonathan T Cox, Ioan Marginean, Ryan T Kelly, Richard D Smith, Keqi Tang

Abstract read
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. On the ionization and ion transmission efficiencies of different ESI-MS interfaces.Journal of the American Society for Mass Spectrometry · 2015
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jonathan T CoxBiological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, 99352, USA.
Ioan Marginean
Ryan T Kelly
Richard D Smith
Keqi Tang

Funding

WORKSHOP AND TRAINING ACTIVITIESP41RR018522 · NCRR · BATTELLE PACIFIC NORTHWEST LABORATORIES · PI SMITH, RICHARD D · 2003 to 2011
$25.1M
Equipment Supplement Request for a Research Resource for Ultra-sensitive High Throughput ProteomicsP41GM103493 · NIGMS · BATTELLE PACIFIC NORTHWEST LABORATORIES · PI SMITH, RICHARD D · 2012 to 2022
$22.6M
Validation and Advanced Development of Emerging TechnologiesR33CA155252 · NCI · BATTELLE PACIFIC NORTHWEST LABORATORIES · PI TANG, KEQI · 2011 to 2013
$1.3M
NCI NIH HHS 1R33CA155252NCI NIH HHS R33 CA155252NCRR NIH HHS P41 RR018522NCRR NIH HHS RR18522NIGMS NIH HHS P41 GM103493NIGMS NIH HHS P41 GM103493-1
6 · The paper itself

Abstract

Arrays of chemically etched emitters with individualized sheath gas capillaries were developed to enhance electrospray ionization (ESI) efficiency at subambient pressures. By incorporating the new emitter array in a subambient pressure ionization with nanoelectrospray (SPIN) source, both ionization efficiency and ion transmission efficiency were significantly increased, providing enhanced sensitivity in mass spectrometric analyses. The SPIN source eliminates the major ion losses of conventional ESI-mass spectrometry (MS) interfaces by placing the emitter in the first reduced pressure region of the instrument. The new ESI emitter array design developed in this study allows individualized sheath gas around each emitter in the array making it possible to generate an array of uniform and stable electrosprays in the subambient pressure (10 to 30 Torr) environment for the first time. The utility of the new emitter arrays was demonstrated by coupling the emitter array/SPIN source with a time of flight (TOF) mass spectrometer. The instrument sensitivity was compared under different ESI source and interface configurations including a standard atmospheric pressure single ESI emitter/heated capillary, single emitter/SPIN and multi-emitter/SPIN configurations using an equimolar solution of nine peptides. The highest instrument sensitivity was observed using the multi-emitter/SPIN configuration in which the sensitivity increased with the number of emitters in the array. Over an order of magnitude MS sensitivity improvement was achieved using multi-emitter/SPIN compared with using the standard atmospheric pressure single ESI emitter/heated capillary interface.

Indexed as

AcetonitrilesEquipment DesignFormatesModels, ChemicalNanotechnologyPeptidesPressureSensitivity and SpecificitySpectrometry, Mass, Electrospray IonizationacetonitrileAcetonitrilesFormatesformic acidPeptides

Identifiers

PMID24676894
PMCPMC4177967

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.