Evidence map›Paper›PMID 24675547›Full record

ArticleScientific reports2014

A transparent broadband ultrasonic detector based on an optical micro-ring resonator for photoacoustic microscopy.

Hao Li, Biqin Dong, Zhen Zhang, Hao F Zhang, Cheng Sun

Abstract read
In one paragraph

Article in Scientific reports, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 75 papers.

0numbers the graph read from it
0cells of the map it votes in
75citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

75 citing papers in PubMed.

  1. Photoacoustics · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Ultrasound sensing with optical microcavities.Light, science & applications · 2024
    Review
  13. Review
  14. Article
  15. ReducedMicroorganisms · 2024
    Article
  16. Review
  17. Review
  18. Article
  19. Review
  20. Article

15 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hao Li1] Department of Biomedical Engineering, Northwestern University, Evanston IL 60208 [2].
Biqin Dong1] Department of Biomedical Engineering, Northwestern University, Evanston IL 60208 [2] Department of Mechanical Engineering, Northwestern University, Evanston IL 60208 [3].
Zhen ZhangDepartment of Mechanical Engineering, Northwestern University, Evanston IL 60208.
Hao F Zhang1] Department of Biomedical Engineering, Northwestern University, Evanston IL 60208 [2] Department of Ophthalmology, Northwestern University, Chicago IL 60611.
Cheng SunDepartment of Mechanical Engineering, Northwestern University, Evanston IL 60208.

Funding

Novel Antiangiogenic Peptides for Treatment of Exudative AMDR24EY022883 · NEI · UNIVERSITY OF WISCONSIN-MADISON · PI SHEIBANI, NADER · 2013 to 2017
$6.2M
Integrated Multidisciplinary Strategies for Detection of Diabetic RetinopathiesRC4EY021357 · NEI · UNIVERSITY OF WISCONSIN-MADISON · PI ASSADI, AMIR H, ASSADI-PORTER, FARIBA M · 2010 to 2010
$3.2M
Multimodal Retinal Functional Imaging for Diabetic RetinopathyR01EY019951 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI FAWZI, AMANI A, JIAO, SHULIANG · 2011 to 2015
$3.0M
NEI NIH HHS 1R01EY019951NEI NIH HHS 1R24EY022883NEI NIH HHS 1RC4EY021357NEI NIH HHS R01 EY019951NEI NIH HHS R24 EY022883NEI NIH HHS RC4 EY021357
6 · The paper itself

Abstract

Photoacoustic microscopy (PAM) does not rely on contrast agent to image the optical absorption contrast in biological tissue. It is uniquely suited for measuring several tissue physiological parameters, such as hemoglobin oxygen saturation, that would otherwise remain challenging. Researchers are designing new clinical diagnostic tools and multimodal microscopic systems around PAM to fully unleash its potential. However, the sizeable and opaque piezoelectric ultrasonic detectors commonly used in PAM impose a serious constraint. Our solution is a coverslip-style optically transparent ultrasound detector based on a polymeric optical micro-ring resonator (MRR) with a total thickness of 250 μm. It enables highly-sensitive ultrasound detection over a wide receiving angle with a bandwidth of 140 MHz, which corresponds to a photoacoustic saturation limit of 287 cm(-1), at an estimated noise-equivalent pressure (NEP) of 6.8 Pa. We also established a theoretical framework for designing and optimizing the MRR for PAM.

Indexed as

Photoacoustic TechniquesUltrasonicsMicroscopy

Identifiers

PMID24675547
PMCPMC3968454

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.