ArticleJournal of clinical microbiology2014
Ability of two commercially available assays (Abbott RealTime HIV-1 and Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Version 2.0) to quantify low HIV-1 RNA Levels (<1,000 copies/milliliter): comparison with clinical samples and NIBSC working reagent for nucleic acid testing assays.
Article in Journal of clinical microbiology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 30 citations in OpenAlex.
- Viral suppression in the context of SARS-CoV-2 among children infected with HIV-1 monitored in five health facilities in Benin.BMC infectious diseases · 2025Article
- Performance Comparison of Xpert HIV-1 Viral Load Assay and Roche Taqman and Abbott M2000 RT in Bamako, Mali.Journal of AIDS & clinical research · 2020Article
- Evaluation of the performance of the Cepheid Xpert HIV-1 Viral Load Assay for quantitative and diagnostic uses.Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2020Article
- Comparison of the Aptima HIV-1 Quant Dx assay with the COBAS AmpliPrep/COBAS TaqMan HIV-1 v2.0 Test for HIV-1 viral load quantification in plasma samples from HIV-1-infected patients.Health science reports · 2018Article
- European Multicenter Study on Analytical Performance of Veris HIV-1 Assay.Journal of clinical microbiology · 2017Article
- Article
- Sensitivity and specificity of dried blood spots for HIV-1 viral load quantification: A laboratory assessment of 3 commercial assays.Medicine · 2016Article
- Evaluation of the Aptima HIV-1 Quant Dx Assay Using Plasma and Dried Blood Spots.Journal of clinical microbiology · 2016Article
- Evaluation of the Aptima(®) HIV-1 Quant Dx assay for HIV-1 RNA viral load detection and quantitation in plasma of HIV-1-infected individuals: A comparison with Abbott RealTime HIV-1 assay.Journal of medical virology · 2016Article
- Evaluation of Performance Characteristics of the Aptima HIV-1 Quant Dx Assay for Detection and Quantitation of Human Immunodeficiency Virus Type 1 in Plasma and Cervicovaginal Lavage Samples.Journal of clinical microbiology · 2016Article
- Evaluation of the RealTime HIV-1, Xpert HIV-1, and Aptima HIV-1 Quant Dx Assays in Comparison to the NucliSens EasyQ HIV-1 v2.0 Assay for Quantification of HIV-1 Viral Load.Journal of clinical microbiology · 2015Article
- Transient detectable viremia and the risk of viral rebound in patients from the Swiss HIV Cohort Study.BMC infectious diseases · 2015Article
- Comparison of Three Different FDA-Approved Plasma HIV-1 RNA Assay Platforms Confirms the Virologic Failure Endpoint of 200 Copies per Milliliter Despite Improved Assay Sensitivity.Journal of clinical microbiology · 2015Article
- Factors Associated with Low-Level Viraemia and Virological Failure: Results from the Austrian HIV Cohort Study.PloS one · 2015Observational
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Concordance between molecular assays may be suboptimal at low HIV-1 viremia levels (<1,000 copies/ml); therefore, it may be difficult to define and compare virologic endpoints for successful and failed therapy. We compared two commercial assays (the Abbott RealTime HIV-1 and the Roche Cobas AmpliPrep/TaqMan HIV-1 version 2.0) for their ability to detect and quantify low viral loads. A comparison was performed using 167 residual clinical samples (with values ranging from "not detected" to 1,000 copies/ml, as measured by the Abbott assay) and the National Institute and Biological Standards and Control (NIBSC) HIV-1 RNA working reagent 1 for nucleic acid amplification techniques (NAT) assays (serially diluted to a range from 1 to 1,000 copies/ml). Quantitative results were compared using Lin's concordance correlation coefficient and a Bland-Altman plot. Concordance with the qualitative results was measured by Cohen's kappa statistic. With clinical samples, the degree of interassay concordance of the qualitative results at a 40-copies/ml HIV-1 RNA threshold was substantial (κ = 0.762); the correlation among the quantified samples was suboptimal (concordance correlation coefficient, 0.728; P < 0.0001); the mean difference of the values between the Roche and Abbott assays was 0.193 log10 copies/ml. Using the HIV-1 RNA working reagent 1 for NAT assays, the results provided by the Roche assay were, on average, 3 times higher than expected, while the Abbott assay showed high accuracy. The Roche assay was highly sensitive, being able to detect a level as low as 3.5 copies/ml HIV-1 RNA with 95% probability. The performance characteristics of each molecular assay should be taken into account when HIV-1 RNA threshold values for "virologic suppression," "virologic failure," "persistent low viral loads," etc., are defined and indicated in the support of clinical decisions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.