ArticleJournal of clinical laboratory analysis2014
Point-of-care fluorescence immunoassay for cardiac panel biomarkers.
Article in Journal of clinical laboratory analysis, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Deep learning-enhanced dual-mode multiplexed optical sensor for point-of-care diagnostics of cardiovascular diseases.Light, science & applications · 2026Article
- Development of a Smartphone-Based Fluorescent Immunochromatographic Assay Strip Reader.Sensors (Basel, Switzerland) · 2020Article
- Automatic Range Adjustment of the Fluorescence Immunochromatographic Assay Based on Image Processing.Sensors (Basel, Switzerland) · 2019Article
- High performance immunochromatographic assay for simultaneous quantitative detection of multiplex cardiac markers based on magnetic nanobeads.Theranostics · 2018Article
- A Fluorescence Immunochromatographic Assay Using Europium (III) Chelate Microparticles for Rapid, Quantitative and Sensitive Detection of Creatine Kinase MB.Journal of fluorescence · 2016Article
- Point-of-care diagnostics for niche applications.Biotechnology advancesReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMyoglobin, creatine kinase-MB isoenzyme (CK-MB), and cardiac troponin I (cTnI) are cardiac biomarkers that are widely used to assist in the early and late diagnoses of acute myocardial infarction (AMI). Here, we present a clinically applicable fluorescence (FL) immunoassay for cardiac biomarkers.
methodsWhole blood was mixed with FL-labeled detector Ab (antibody) and then loaded onto a capture Ab-immobilized strip in a test cartridge. The FL intensities at test and control line on the strip were obtained and converted in a laser FL scanner to determine the concentration of biomarker. The analytical performance of immunoassay system was evaluated by linearity and imprecision tests. The comparability of the FL immunoassay method was examined with a reference method.
resultsFL intensities and the levels of myoglobin, CK-MB, and cTnI displayed good linearity and high correlations (r = 0.999, 0.998, and 0.989, respectively). The coefficient of variations (CVs) of imprecision for all cardiac biomarkers were less than 8% in both intra- and interassays. When the results from the developed method and bioMerieux VIDAS assay were analyzed by Bland-Altman plot and Passing-Bablok plot, the two assay methods were in good agreement.
conclusionThe FL immunoassay system can provide a platform for point-of-care testing (POCT), and it is an easy, fast, and reliable method for the quantification of cardiac biomarkers.